Skip to content

Bit in reduntant OTP registers not updated if mayority vote is 0, but main register is 1. #330

Description

@erwin3169

picotool otp get CRIT1.SECURE_DEBUG_DISABLE
ROW 0x0040: OTP_DATA_CRIT1
"Page 1 critical boot flags (RBIT-8)"
RAW_VALUE=0x000007;0x000005;0x000005;0x000005;0x000005;0x000005;0x000005;0x000005(WARNING - REDUNDANT ROWS AREN'T EQUAL)
VALUE 0x000005

field SECURE_DEBUG_DISABLE (bit 1) = 0
    "Disable Secure debug access"

picotool otp set CRIT1.SECURE_DEBUG_DISABLE 1
ROW 0x0040 OLD_VALUE=0x000007: OTP_DATA_CRIT1
"Page 1 critical boot flags (RBIT-8)"
field SECURE_DEBUG_DISABLE (bit 1)

I am unable to disable secure debug, as picotool refuses to write a 1 to the redundant registers. Any way to solve this?