Notifications
You must be signed in to change notification settings - Fork 6
Expand file tree
/
Copy pathdeye.lua
More file actions
624 lines (560 loc) · 22.4 KB
/
Copy pathdeye.lua
File metadata and controls
624 lines (560 loc) · 22.4 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
-- Deye Hybrid Inverter Driver
-- Ported from sourceful-hugin/device-support/drivers/lua/deye.lua
-- Emits: PV, Battery, Meter telemetry + battery control
-- Protocol: Modbus TCP (holding registers throughout)
-- Byte order: Little-Endian for multi-register U32 values
DRIVER = {
host_api_min = 1,
host_api_max = 1,
id = "deye",
name = "Deye hybrid inverter",
manufacturer = "Deye",
version = "1.0.1",
protocols = { "modbus" },
capabilities = { "meter", "pv", "battery" },
description = "Deye SUN-SG series hybrid inverters via Modbus. Auto-detects LV vs HV battery at init.",
homepage = "https://www.deyeinverter.com",
authors = { "FTW contributors" },
tested_models = { "SUN-SG03LP1", "SUN-SG04LP3" },
verification_status = "experimental",
verification_notes = "Ported from a reference implementation. Not yet verified against live hardware on a FTW site.",
connection_defaults = {
port = 502,
unit_id = 1,
},
}
--
-- Register conventions (all holding, FC 0x03/0x06):
-- 0 : device type code. High byte == 6 → HV battery variant.
-- 3-7 : serial number, packed 2 bytes/register, big-endian within each word.
-- 20-21 : rated power, U32 LE × 0.1 kW
-- 141 : energy management mode (0=Selling First, 1=Zero Export To Load,
-- 2=Zero Export To CT, 3=External EMS / forced)
-- 143 : grid-charge enable (bit 0)
-- 144 : power limit for forced charge/discharge (W)
-- 217 : battery temperature, U16, actual C = (val - 1000) / 10
-- 516-519 : battery charge/discharge energy counters, U32 LE × 0.1 kWh
-- 522-525 : grid import/export energy, U32 LE × 0.1 kWh
-- 534-535 : total PV generation, U32 LE × 0.1 kWh
-- 541 : heatsink temperature, U16 × 0.1 C
-- 587-591 : battery V/SoC/power/current
-- 598-612 : per-phase V/current, grid frequency
-- 619, 622 : total + per-phase meter power (I16, W)
-- 672-679 : PV power + MPPT V/A
--
-- Sign convention (site view, see docs/site-convention.md):
-- pv.w : always negative (generation flowing into the site)
-- battery.w : positive = charging, negative = discharging
-- meter.w : positive = importing, negative = exporting
PROTOCOL = "modbus"
-- Cached across polls
local is_hv = false
local sn_read = false
local control_initialized = false
local rated_power_w = 0
-- Grid → battery charge current cap (reg 128). Sized to the install's main
-- fuse / grid subscription, not the battery's max charge rate. Overridable
-- via config.max_grid_charge_a; default 31 A matches Zap's init profile.
local grid_charge_current_a = 31
-- These limits are read during driver_init(), so their declarations must be
-- above that function. Declaring them near the command helpers made init see
-- nil globals instead of the intended driver-local defaults.
local soc_max = 100
local soc_min = 20
----------------------------------------------------------------------------
-- Initialization
----------------------------------------------------------------------------
function driver_init(config)
host.set_make("Deye")
-- Strict HV detect (reg 0 raw value == 6 is the HV variant per Deye
-- protocol docs). Earlier ports also accepted the value in the high
-- byte, but the Zap reference on real hardware uses strict equality
-- and we match that to avoid false HV positives on LV units.
local ok, mode_regs = pcall(host.modbus_read, 0, 1, "holding")
if ok and mode_regs then
local val = mode_regs[1]
is_hv = (val == 6)
host.log("info", string.format("Deye: device type 0x%04x (%s battery)",
val, is_hv and "HV" or "LV"))
else
host.log("warn", "Deye: device type read failed; assuming LV")
end
-- Rated power drives curtailment ceiling and the init profile's max-sell
-- register. Prefer an operator-supplied value from YAML, else pull the
-- device-reported rating from regs 20-21 (U32 LE × 0.1 kW), else default.
if config and type(config) == "table" and tonumber(config.rated_w) then
rated_power_w = math.floor(tonumber(config.rated_w))
else
local ok_r, rated_regs = pcall(host.modbus_read, 20, 2, "holding")
if ok_r and rated_regs then
rated_power_w = math.floor(
host.decode_u32_le(rated_regs[1], rated_regs[2]) * 0.1 * 1000)
end
end
if rated_power_w <= 0 then rated_power_w = 5000 end
if config and type(config) == "table" and tonumber(config.max_grid_charge_a) then
local a = math.floor(tonumber(config.max_grid_charge_a))
if a < 0 then a = 0 end
if a > 185 then a = 185 end -- register ceiling per Deye V105.3 spec
grid_charge_current_a = a
end
local function clamp_soc(v)
v = math.floor(v)
if v < 0 then v = 0 end
if v > 100 then v = 100 end
return v
end
if config and type(config) == "table" then
if tonumber(config.soc_max) then soc_max = clamp_soc(tonumber(config.soc_max)) end
if tonumber(config.soc_min) then soc_min = clamp_soc(tonumber(config.soc_min)) end
if soc_min > soc_max then
host.log("warn", string.format(
"Deye: soc_min (%d) > soc_max (%d); swapping", soc_min, soc_max))
soc_min, soc_max = soc_max, soc_min
end
end
host.log("info", string.format(
"Deye: driver_init (rated=%.0fW, max_grid_charge=%dA, soc=%d..%d)",
rated_power_w, grid_charge_current_a, soc_min, soc_max))
end
----------------------------------------------------------------------------
-- Telemetry polling
----------------------------------------------------------------------------
function driver_poll()
-- Read serial number once. Registers 3..7 hold 10 ASCII bytes
-- (2 chars per register, big-endian within each word).
if not sn_read then
local ok, sn_regs = pcall(host.modbus_read, 3, 5, "holding")
if ok and sn_regs then
local sn = ""
for i = 1, 5 do
local hi = math.floor(sn_regs[i] / 256)
local lo = sn_regs[i] % 256
if hi > 32 and hi < 127 then sn = sn .. string.char(hi) end
if lo > 32 and lo < 127 then sn = sn .. string.char(lo) end
end
if #sn > 0 then
host.set_sn(sn)
sn_read = true
end
end
end
-- ---- PV ----
-- PV1-PV4 power: 672-675, U16 each (×1 LV, ×10 HV)
local ok_pvw, pvw_regs = pcall(host.modbus_read, 672, 4, "holding")
local pv_total_w = 0
if ok_pvw and pvw_regs then
local pv_scale = is_hv and 10 or 1
for i = 1, 4 do
pv_total_w = pv_total_w + pvw_regs[i] * pv_scale
end
end
-- MPPT1 V/A: 676-677, U16 × 0.1 each
local ok_m1, m1_regs = pcall(host.modbus_read, 676, 2, "holding")
local mppt1_v, mppt1_a = 0, 0
if ok_m1 and m1_regs then
mppt1_v = m1_regs[1] * 0.1
mppt1_a = m1_regs[2] * 0.1
end
-- MPPT2 V/A: 678-679, U16 × 0.1 each
local ok_m2, m2_regs = pcall(host.modbus_read, 678, 2, "holding")
local mppt2_v, mppt2_a = 0, 0
if ok_m2 and m2_regs then
mppt2_v = m2_regs[1] * 0.1
mppt2_a = m2_regs[2] * 0.1
end
-- Total generation: 534-535, U32 LE × 0.1 kWh
local ok_gen, gen_regs = pcall(host.modbus_read, 534, 2, "holding")
local pv_gen_wh = 0
if ok_gen and gen_regs then
pv_gen_wh = host.decode_u32_le(gen_regs[1], gen_regs[2]) * 0.1 * 1000
end
-- Rated power: 20-21, U32 LE × 0.1 kW
local ok_rated, rated_regs = pcall(host.modbus_read, 20, 2, "holding")
local rated_w = 0
if ok_rated and rated_regs then
rated_w = host.decode_u32_le(rated_regs[1], rated_regs[2]) * 0.1 * 1000
end
-- Heatsink temperature: 541, U16 × 0.1 C
local ok_temp, temp_regs = pcall(host.modbus_read, 541, 1, "holding")
local heatsink_c = 0
if ok_temp and temp_regs then
heatsink_c = temp_regs[1] * 0.1
end
host.emit("pv", {
w = -pv_total_w, -- negate: PV generation is negative in site convention
mppt1_v = mppt1_v,
mppt1_a = mppt1_a,
mppt2_v = mppt2_v,
mppt2_a = mppt2_a,
lifetime_wh = pv_gen_wh,
rated_w = rated_w,
temp_c = heatsink_c,
})
host.emit_metric("pv_mppt1_v", mppt1_v)
host.emit_metric("pv_mppt1_a", mppt1_a)
host.emit_metric("pv_mppt2_v", mppt2_v)
host.emit_metric("pv_mppt2_a", mppt2_a)
host.emit_metric("inverter_temp_c", heatsink_c)
-- ---- Battery ----
-- Battery voltage: 587, U16 (×0.01 LV, ×0.1 HV)
local ok_bv, bv_regs = pcall(host.modbus_read, 587, 1, "holding")
local bat_v = 0
if ok_bv and bv_regs then
bat_v = bv_regs[1] * (is_hv and 0.1 or 0.01)
end
-- Battery SoC: 588, U16 percent → 0..1 fraction
local ok_bsoc, bsoc_regs = pcall(host.modbus_read, 588, 1, "holding")
local bat_soc = 0
if ok_bsoc and bsoc_regs then
bat_soc = bsoc_regs[1] / 100
end
-- Battery power: 590, I16 (×1 LV, ×10 HV). Deye native: positive = charging.
local ok_bw, bw_regs = pcall(host.modbus_read, 590, 1, "holding")
local bat_w = 0
if ok_bw and bw_regs then
local bat_scale = is_hv and 10 or 1
bat_w = host.decode_i16(bw_regs[1]) * bat_scale
end
-- Battery current: 591, I16 × 0.01 A
local ok_ba, ba_regs = pcall(host.modbus_read, 591, 1, "holding")
local bat_a = 0
if ok_ba and ba_regs then
bat_a = host.decode_i16(ba_regs[1]) * 0.01
end
-- Battery temperature: 217, U16 offset-encoded (actual = (val-1000)/10)
local ok_btemp, btemp_regs = pcall(host.modbus_read, 217, 1, "holding")
local bat_temp = 0
if ok_btemp and btemp_regs then
bat_temp = (btemp_regs[1] - 1000) / 10
end
-- Battery charge energy: 516-517, U32 LE × 0.1 kWh
local ok_bchg, bchg_regs = pcall(host.modbus_read, 516, 2, "holding")
local bat_charge_wh = 0
if ok_bchg and bchg_regs then
bat_charge_wh = host.decode_u32_le(bchg_regs[1], bchg_regs[2]) * 0.1 * 1000
end
-- Battery discharge energy: 518-519, U32 LE × 0.1 kWh
local ok_bdis, bdis_regs = pcall(host.modbus_read, 518, 2, "holding")
local bat_discharge_wh = 0
if ok_bdis and bdis_regs then
bat_discharge_wh = host.decode_u32_le(bdis_regs[1], bdis_regs[2]) * 0.1 * 1000
end
-- Deye reports positive = charging already, which matches site convention.
host.emit("battery", {
w = bat_w,
v = bat_v,
a = bat_a,
soc = bat_soc,
temp_c = bat_temp,
charge_wh = bat_charge_wh,
discharge_wh = bat_discharge_wh,
})
host.emit_metric("battery_dc_v", bat_v)
host.emit_metric("battery_dc_a", bat_a)
host.emit_metric("battery_temp_c", bat_temp)
-- ---- Meter ----
-- Per-phase voltage: 598-600, U16 × 0.1 V
local ok_lv, lv_regs = pcall(host.modbus_read, 598, 3, "holding")
local l1_v, l2_v, l3_v = 0, 0, 0
if ok_lv and lv_regs then
l1_v = lv_regs[1] * 0.1
l2_v = lv_regs[2] * 0.1
l3_v = lv_regs[3] * 0.1
end
-- Grid frequency: 609, U16 × 0.01 Hz
local ok_hz, hz_regs = pcall(host.modbus_read, 609, 1, "holding")
local hz = 0
if ok_hz and hz_regs then
hz = hz_regs[1] * 0.01
end
-- Per-phase current: 610-612, I16 × 0.01 A
local ok_la, la_regs = pcall(host.modbus_read, 610, 3, "holding")
local l1_a, l2_a, l3_a = 0, 0, 0
if ok_la and la_regs then
l1_a = host.decode_i16(la_regs[1]) * 0.01
l2_a = host.decode_i16(la_regs[2]) * 0.01
l3_a = host.decode_i16(la_regs[3]) * 0.01
end
-- Total meter power: 619, I16 W (positive = import, negative = export)
local ok_tw, tw_regs = pcall(host.modbus_read, 619, 1, "holding")
local meter_w = 0
if ok_tw and tw_regs then
meter_w = host.decode_i16(tw_regs[1])
end
-- Per-phase power: 622-624, I16 W
local ok_lw, lw_regs = pcall(host.modbus_read, 622, 3, "holding")
local l1_w, l2_w, l3_w = 0, 0, 0
if ok_lw and lw_regs then
l1_w = host.decode_i16(lw_regs[1])
l2_w = host.decode_i16(lw_regs[2])
l3_w = host.decode_i16(lw_regs[3])
end
-- Import energy: 522-523, U32 LE × 0.1 kWh
local ok_imp, imp_regs = pcall(host.modbus_read, 522, 2, "holding")
local import_wh = 0
if ok_imp and imp_regs then
import_wh = host.decode_u32_le(imp_regs[1], imp_regs[2]) * 0.1 * 1000
end
-- Export energy: 524-525, U32 LE × 0.1 kWh
local ok_exp, exp_regs = pcall(host.modbus_read, 524, 2, "holding")
local export_wh = 0
if ok_exp and exp_regs then
export_wh = host.decode_u32_le(exp_regs[1], exp_regs[2]) * 0.1 * 1000
end
host.emit("meter", {
w = meter_w,
l1_w = l1_w,
l2_w = l2_w,
l3_w = l3_w,
l1_v = l1_v,
l2_v = l2_v,
l3_v = l3_v,
l1_a = l1_a,
l2_a = l2_a,
l3_a = l3_a,
hz = hz,
import_wh = import_wh,
export_wh = export_wh,
})
host.emit_metric("meter_l1_w", l1_w)
host.emit_metric("meter_l2_w", l2_w)
host.emit_metric("meter_l3_w", l3_w)
host.emit_metric("meter_l1_v", l1_v)
host.emit_metric("meter_l2_v", l2_v)
host.emit_metric("meter_l3_v", l3_v)
host.emit_metric("meter_l1_a", l1_a)
host.emit_metric("meter_l2_a", l2_a)
host.emit_metric("meter_l3_a", l3_a)
host.emit_metric("grid_hz", hz)
return 5000
end
----------------------------------------------------------------------------
-- Battery control
----------------------------------------------------------------------------
--
-- Register map (holding, all FC 0x06):
-- 108 : Max battery charge current (A)
-- 109 : Max battery discharge current (A)
-- 128 : Charging current (A)
-- 129 : Generator charge enable (0/1)
-- 130 : Utility (grid) charge enable (0/1)
-- 141 : Energy management mode
-- 0 = Selling First (self-consume)
-- 1 = Load First (self-consume, battery tops up after load)
-- 2 = Zero Export To CT
-- 3 = External EMS / Forced
-- 142 : Limit control
-- 0 = enable discharge
-- 1 = no CT clamps
-- 2 = extraposition enable (forced-setpoint gate)
-- 143 : Max sell power (W, scaled HV/LV) — also curtail setpoint
-- 145 : PV sell enable (0/1)
-- 146 : Advanced peak-shaving enable
-- 148 : TOU timestamp 1
-- 149 : TOU timestamp 2
-- 154 : Battery output (discharge) power (W, scaled HV/LV)
-- 166 : Battery SoC target (percent, 20=min / 100=max)
-- 172 : Charge enable (3 = grid + PV)
-- 178 : Control-board special function (vendor magic 11816)
-- 587 : Battery voltage (HV × 0.1 V, LV × 0.01 V)
--
-- HV models encode 10 W per register unit on 143/154; LV models 1 W.
-- Charging is expressed as current on reg 108 (A = W / V).
-- Deye firmware tolerates ≥50 ms between consecutive holding writes.
local REG_MAX_CHARGE_A = 108
local REG_MAX_DISCHARGE_A = 109
local REG_CHARGE_CURRENT = 128
local REG_GEN_CHARGE_ENABLE = 129
local REG_GRID_CHARGE_ENABLE = 130
local REG_EMS_MODE = 141
local REG_LIMIT_CONTROL = 142
local REG_MAX_SELL_POWER = 143
local REG_PV_SELL_ENABLE = 145
local REG_PEAK_SHAVING = 146
local REG_TOU_TS1 = 148
local REG_TOU_TS2 = 149
local REG_DISCHARGE_POWER = 154
local REG_SOC_TARGET = 166
local REG_CHARGE_ENABLE = 172
local REG_SPECIAL_FUNC = 178
local REG_BATTERY_VOLTAGE = 587
local EMS_LOAD_FIRST = 1 -- native self-consumption, battery tops up load
local EMS_EXTERNAL = 3 -- forced setpoints via reg 108/154
-- SoC targets written to reg 166. Charge commands aim for soc_max,
-- discharge commands floor at soc_min. Defaults match Zap; overridable
-- via config.soc_max / config.soc_min.
local CHARGE_CURRENT_DEFAULT_A = 31 -- matches Zap init profile
local WRITE_DELAY_MS = 50
local function write_reg(addr, val)
local err = host.modbus_write(addr, val)
host.sleep(WRITE_DELAY_MS)
if err ~= nil and err ~= "" then
host.log("warn", string.format("Deye: write %d=%d failed: %s",
addr, val, tostring(err)))
return false
end
return true
end
local function write_sequence(writes)
for i = 1, #writes do
if not write_reg(writes[i][1], writes[i][2]) then return false end
end
return true
end
local function clamp_u16(v)
if v < 0 then return 0 end
if v > 65535 then return 65535 end
return math.floor(v)
end
-- HV registers are in 10 W units; LV in 1 W. Returns the register value.
local function scale_power(watts)
local abs_w = math.abs(watts)
if is_hv then abs_w = abs_w / 10 end
return clamp_u16(abs_w)
end
local function read_battery_voltage()
local ok, regs = pcall(host.modbus_read, REG_BATTERY_VOLTAGE, 1, "holding")
if not (ok and regs) then return nil end
return regs[1] * (is_hv and 0.1 or 0.01)
end
-- Full init profile (13 writes). Reapplied whenever we re-enter forced
-- mode after a cleanup/default-mode revert so the inverter has a known
-- baseline for charge-current limits, peak-shaving and TOU boundaries.
local function initialize_control()
local max_sell = scale_power(rated_power_w)
local ok = write_sequence({
{ REG_SPECIAL_FUNC, 11816 },
{ REG_MAX_CHARGE_A, CHARGE_CURRENT_DEFAULT_A },
{ REG_MAX_DISCHARGE_A, CHARGE_CURRENT_DEFAULT_A },
{ REG_CHARGE_CURRENT, grid_charge_current_a },
{ REG_GEN_CHARGE_ENABLE, 1 },
{ REG_GRID_CHARGE_ENABLE, 1 },
{ REG_EMS_MODE, EMS_EXTERNAL },
{ REG_LIMIT_CONTROL, 2 },
{ REG_MAX_SELL_POWER, max_sell },
{ REG_PV_SELL_ENABLE, 1 },
{ REG_PEAK_SHAVING, 255 },
{ REG_TOU_TS1, 0 },
{ REG_TOU_TS2, 2355 },
})
control_initialized = ok
if ok then
host.log("info", string.format(
"Deye: control initialized (%s, rated=%dW, max_sell_reg=%d)",
is_hv and "HV" or "LV", rated_power_w, max_sell))
else
host.log("error", "Deye: control init failed")
end
return ok
end
local function ensure_initialized()
return control_initialized or initialize_control()
end
-- Site convention: power_w > 0 = charge, < 0 = discharge, 0 = stop both.
-- Charging path converts watts to amps using the live battery voltage —
-- the Deye charge register is current, not power.
local function set_battery_power(power_w)
if not ensure_initialized() then return false end
if power_w > 0 then
local voltage = read_battery_voltage()
if not voltage or voltage <= 0.1 then
host.log("error", string.format(
"Deye: charge rejected, invalid battery voltage %s",
tostring(voltage)))
return false
end
local current = math.floor(power_w / voltage + 0.5)
if current < 1 then current = 1 end
current = clamp_u16(current)
host.log("debug", string.format("Deye: charge %dW @ %.2fV → %dA",
power_w, voltage, current))
return write_sequence({
{ REG_SOC_TARGET, soc_max },
{ REG_MAX_CHARGE_A, current },
{ REG_CHARGE_ENABLE, 3 }, -- 3 = grid + PV
})
end
if power_w < 0 then
local power_val = scale_power(power_w)
host.log("debug", string.format("Deye: discharge %dW → reg=%d",
math.abs(power_w), power_val))
return write_sequence({
{ REG_DISCHARGE_POWER, power_val },
{ REG_SOC_TARGET, soc_min },
{ REG_LIMIT_CONTROL, 0 }, -- enable discharge
})
end
-- Zero setpoint: hold forced mode but drive both directions to 0 so
-- the inverter idles without leaving external-EMS control.
host.log("debug", "Deye: setpoint 0W (hold)")
return write_sequence({
{ REG_MAX_CHARGE_A, 0 },
{ REG_DISCHARGE_POWER, 0 },
})
end
local function enable_curtailment(power_w)
if not ensure_initialized() then return false end
if power_w < 0 then power_w = 0 end
local limit = scale_power(power_w)
host.log("debug", string.format("Deye: curtail → %dW (reg=%d)",
power_w, limit))
return write_sequence({
{ REG_PV_SELL_ENABLE, 1 },
{ REG_MAX_SELL_POWER, limit },
})
end
local function disable_curtailment()
if not ensure_initialized() then return false end
local limit = scale_power(rated_power_w)
host.log("debug", string.format("Deye: curtail disabled → %dW", rated_power_w))
return write_sequence({
{ REG_PV_SELL_ENABLE, 1 },
{ REG_MAX_SELL_POWER, limit },
})
end
-- Drop the inverter back to native self-consumption. Mirrors Zap's
-- applyDefaultSelfConsumptionMode(): Load First + PV sell + TOU on,
-- grid-charging off, CT-clamp extraposition left enabled.
local function set_self_consumption()
local ok = write_sequence({
{ REG_LIMIT_CONTROL, 2 },
{ REG_EMS_MODE, EMS_LOAD_FIRST },
{ REG_PV_SELL_ENABLE, 1 },
{ REG_PEAK_SHAVING, 1 },
{ REG_GRID_CHARGE_ENABLE, 0 },
})
if ok then control_initialized = false end
return ok
end
function driver_command(action, power_w, cmd)
if action == "init" then
return initialize_control()
elseif action == "battery" then
return set_battery_power(power_w or 0)
elseif action == "curtail" then
return enable_curtailment(power_w or 0)
elseif action == "curtail_disable" then
return disable_curtailment()
elseif action == "deinit" then
return set_self_consumption()
end
host.log("debug", "Deye: unsupported action: " .. tostring(action))
return false
end
-- Watchdog fallback: always revert to autonomous self-consumption so the
-- device doesn't get stuck in a forced mode when the EMS goes offline.
function driver_default_mode()
host.log("info", "Deye: watchdog → reverting to self-consumption")
set_self_consumption()
end
function driver_cleanup()
pcall(set_self_consumption)
is_hv = false
sn_read = false
control_initialized = false
rated_power_w = 0
grid_charge_current_a = 31
soc_max = 100
soc_min = 20
end