Notifications
You must be signed in to change notification settings - Fork 6
Expand file tree
/
Copy pathferroamp.lua
More file actions
1096 lines (1026 loc) · 53.8 KB
/
Copy pathferroamp.lua
File metadata and controls
1096 lines (1026 loc) · 53.8 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
-- ferroamp.lua
-- Ferroamp EnergyHub MQTT driver
-- Emits: PV, Battery, Meter telemetry
DRIVER = {
host_api_min = 1,
host_api_max = 1,
id = "ferroamp",
name = "Ferroamp EnergyHub",
manufacturer = "Ferroamp",
version = "1.0.0",
protocols = { "mqtt" },
capabilities = { "meter", "pv", "battery" },
description = "Ferroamp EnergyHub with ESO battery + SSO solar strings (3-phase).",
homepage = "https://ferroamp.com",
authors = { "FTW contributors" },
tested_models = { "EnergyHub XL" },
verification_status = "production",
verified_by = { "frahlg@homelab-rpi:14d" },
verified_at = "2026-04-18",
verification_notes = "In continuous use on 3-phase 16A SE site, MPC + dispatch control loop exercised daily.",
connection_defaults = {
port = 1883,
username = "extapi",
password = "ferroampExtApi",
},
}
--
-- Subscribes to:
-- extapi/data/ehub - main hub data (grid, frequency, energy counters, PV summary)
-- extapi/data/eso - battery storage object (SoC, battery power, voltage, current)
-- extapi/data/sso - solar string object (per-string PV power)
--
-- Ferroamp payload format: {"key": {"val": value}} or {"key": {"L1": v1, "L2": v2, "L3": v3}}
-- Energy counters are in mJ (millijoules); convert to Wh: mJ / 3,600,000
--
-- Sign convention:
-- PV w: always negative (generation)
-- Battery w: positive = charging, negative = discharging
-- Meter w: positive = import, negative = export
PROTOCOL = "mqtt"
-- Cached state from each topic
local ehub_data = nil
local sso_data = nil
-- ESO state is per-unit. Ferroamp publishes one extapi/data/eso message
-- per ESO; a single-slot cache always reflected only the most-recently-
-- published unit, halving (or worse) reported battery power in N-ESO
-- installations. Real incident 2026-05-24 at a 2×ESO site: 42's bat_w
-- was exactly half of ehub.pbat, the controller's grid-chase loop fed
-- on the wrong number, and dispatch never converged on grid_target.
-- The fix is to key each ESO by its `id` field and aggregate at emit
-- time; messages without an `id` fall under a synthetic key so
-- single-ESO firmware / sims keep behaving identically.
local eso_data_by_id = {} -- id -> payload table
local eso_ts_by_id = {} -- id -> last arrival ms
-- Last-arrival timestamp per topic (host.millis()). The EnergyHub
-- normally publishes ehub at ~1 Hz; if it goes silent (power off,
-- fuse blow, broker partition) the cached tables above stay
-- populated. Without per-topic age checks the driver would re-emit
-- last-known values on every poll, host.emit would re-stamp
-- LastSuccess, and the watchdog could not flip the driver offline.
-- Real incident: 2026-05-02 fuse blow left ferroamp emitting
-- pv_w=-3996.7040 / meter_w=-7294.0490 identical to four decimals
-- for 30+ minutes while the EnergyHub itself was unpowered.
local ehub_ts = 0
local sso_ts = 0
-- ehub.soc cache. Ferroamp's ehub topic emits the system SoC field
-- on a coarser cadence than the other ehub fields (~1 in 9 messages
-- on the firmware we tested 2026-05-26, ~once every ~9s). If we read
-- it directly off the latest ehub_data cache we'd see it only when
-- the most recent message happened to include it, otherwise nil —
-- and battery.soc would flap between the ehub value and the fallback
-- every poll. Cache the last-observed soc and its timestamp so it
-- stays the authoritative reading until it ages out.
local last_ehub_soc = nil
local last_ehub_soc_ts = 0
local EHUB_SOC_STALE_MS = 60000 -- ~6× the observed publish interval
-- Treat cached topic data as stale beyond this age. EnergyHub
-- publishes ehub at ~1 Hz and eso/sso slightly slower; 30 s gives
-- generous slack for a WiFi blip or broker reconnect without
-- flipping the driver offline.
local STALE_AFTER_MS = 30000
-- Optional config knob: when `skip_battery` is true the driver will
-- NOT emit battery telemetry even when the ESO/pbat fields are
-- present on the wire. Useful for dev setups that want a PV-only
-- dashboard fed by the otherwise full-featured Ferroamp sim.
local SKIP_BATTERY = false
local last_control_mode = nil
-- Optional config knob: per-ESO usable capacity in kWh, keyed on the
-- ESO id string (matches the `id.val` field in extapi/data/eso). When
-- provided, battery.soc is reported as a capacity-weighted aggregate
-- instead of the flat arithmetic mean. Useful on heterogeneous clusters
-- where Ferroamp's own app shows a different number than our mean:
-- e.g. 2×ESO-15 (newer) at 87% + 2×ESO-7.7 (older) at 38.6% averages to
-- 62.8%, but Ferroamp's capacity-weighted view sits closer to 70%+.
-- Format in YAML:
-- eso_capacity_kwh:
-- "26040075": 15.0
-- "21030026": 7.7
-- Units with no entry contribute their soc with weight = average of the
-- configured weights (so a partial config doesn't silently zero them).
local ESO_CAPACITY_KWH = {}
-- Multi-ESO dispatch scaling. The EnergyHub divides a discharge/charge
-- setpoint evenly across ALL ESOs it knows about, including units pinned
-- at their SoC floor/ceiling that physically refuse to respond. On a
-- 4×ESO site with 2 units floored at min SoC, asking for 1.3 kW resulted
-- in only ~0.66 kW delivered — the EHub commanded ~330 W per ESO, the
-- two active units honored it, the two floored ones produced 0. Verified
-- live on 2026-05-26 (Stefan's site). To compensate we count how many
-- ESOs are *currently capable* of the requested direction and pre-scale
-- the outgoing command by N_total / N_capable.
--
-- Margins are 5% inside the typical Ferroamp floor (10%) / ceiling (100%)
-- to avoid oscillating at the edge — within ~2% of its limit an ESO
-- already refuses dispatch, so a 5% margin is comfortably outside the
-- "willing but limited" band.
--
-- Caveats this scaling has and does NOT solve:
-- * Behaviour is empirical (single live observation, firmware vintage
-- unknown). If EHub firmware ever rebalances to active units the
-- scaling double-compensates — diff `eso_dispatch_commanded_w` vs
-- the next tick's `battery.w` to spot that.
-- * The upstream dispatch clamp (config.Driver.max_charge_w / fuse
-- guard, dispatch.go ~1685) caps the *target* power, then we
-- multiply on the wire by up to MAX_DISPATCH_SCALE. That bound
-- protects fuse + inverter rating; if you raise it, also revisit
-- the per-driver caps in config.yaml.
local DISCHARGE_FLOOR_SOC = 0.15
local CHARGE_CEIL_SOC = 0.95
-- PV-curtail release power (watts). When ComputePVCurtail releases this
-- driver (curtail_disable action), the dispatcher historically wanted us
-- to send `pplim arg=0`. Ferroamp's extapi treats that as "limit PV to
-- 0 W" — same wire bytes as a release would have, opposite semantics —
-- and the inverter sticks at 0 W PV until a portal reset. So we publish
-- pplim arg=PPLIM_RELEASE_W instead, which the operator sets to the
-- inverter's nominal max (e.g. 15000 for a 15 kW SSO). Default 0 means
-- "do not publish a release at all", which preserves whatever pplim
-- Ferroamp last received. Override via config.pplim_release_w in
-- config.yaml. 2026-05-27 incident: dispatching `pplim arg=0` bricked
-- the live SE4 site for 30+ minutes; recovery required a Ferroamp
-- portal reset.
local PPLIM_RELEASE_W = 0
-- Stuck-pplim self-healing watchdog. If the SSO reports DC bus voltage
-- (paneler aktiva) AND zero PV current AND no fault for STUCK_PV_AFTER_MS
-- continuous, we treat that as the sticky-pplim trap signature and
-- auto-publish `pplim arg=PPLIM_RELEASE_W` to recover. Operator opts in
-- by setting PPLIM_RELEASE_W > 0 — without that we just log a warning
-- because we have no safe release value. The recovery has a cooldown
-- (STUCK_PV_RECOVERY_COOLDOWN_MS) so a persistent issue can't loop us
-- into command-spam. 2026-05-27 incident background: PR #367 + #372.
local STUCK_PV_AFTER_MS = 10 * 60 * 1000 -- 10 minutes
local STUCK_PV_RECOVERY_COOLDOWN_MS = 5 * 60 * 1000 -- 5 minutes
local STUCK_PV_DC_V_THRESHOLD = 200 -- volts on the DC bus
local stuck_pv_since_ms = -1 -- -1 = not stuck
local stuck_pv_last_recovery_ms = -1 -- -1 = never recovered
local stuck_pv_recovery_count = 0
-- Cap on the N_total/N_capable multiplier so a transient "only 1 of 4
-- capable" snapshot can't quadruple the on-wire setpoint past inverter
-- rating before the next poll corrects it. 2.0 covers the common
-- 2-of-4 / 1-of-2 cases; deeper imbalance is left under-delivered (a
-- safe failure mode — planner sees the gap and re-plans).
local MAX_DISPATCH_SCALE = 2.0
local last_eso_count = 0
local last_eso_discharge_capable = 0
local last_eso_charge_capable = 0
-- Delivery-ratio scaling. The EnergyHub splits a charge/discharge setpoint
-- evenly across ALL ESOs; a unit that's saturated (CV taper near full, the
-- EHub balancing toward lower-SoC units, voltage/thermal limit) absorbs
-- almost none of its even share, so the pack delivers far less than we ask.
-- Instead of toggling units active/inactive on a power threshold (which
-- flaps when a saturated unit trickles a little — e.g. 170 W against a
-- ~650 W share still reads "charging"), we scale the on-wire setpoint by
-- the inverse of the pack's *delivery efficiency*:
-- eff = |delivered battery W| / |last on-wire setpoint W|
-- scale = N_eso / N_active (clamped to MAX_DISPATCH_SCALE)
-- where N_active counts the units that ACTUALLY DELIVERED power in the
-- commanded direction last tick — measured from per-ESO ubat*ibat, NOT from
-- SoC. An ESO at its limit (full on charge, empty on discharge) delivers ~0
-- and is excluded; the up-scale then lifts the delivering units to cover the
-- stuck unit's even share. Because the active units split exactly the
-- commanded power between them, the pack delivers the commanded total and
-- NEVER more — scale is 1.0 when all units deliver, so this can't over-
-- discharge/over-charge (unlike a delivery-efficiency ratio, whose estimate
-- got dragged low by full units during charge and, applied to discharge,
-- drove a 1.66x over-discharge dumping ~2.7 kW to grid — Stefan 2026-06-10).
-- An ESO is "active" if it delivers at least half its 1/N share of the
-- on-wire setpoint (ACTIVE_SHARE_FRAC). The SoC-capable counts below remain,
-- but ONLY for the "every unit floored/ceilinged → idle" guard.
local ACTIVE_SHARE_FRAC = 0.5 -- min fraction of the 1/N share to count a unit "active"
local SCALE_FB_MIN_W = 200 -- only measure delivery when on-wire command >= this
local last_eso_active_charge = nil -- units delivering charge last tick (nil until measured)
local last_eso_active_discharge = nil -- units delivering discharge last tick
local last_on_wire_w = 0 -- magnitude of the last (scaled) on-wire setpoint sent
local last_commanded_w = 0 -- magnitude of the last DISPATCH command (pre-scale); the
-- active threshold keys off THIS, not the scaled on-wire
-- value, so a rising scale can't inflate the threshold and
-- spuriously exclude units that are delivering (feedback bug)
-- Cumulative count of Ferroamp extapi `nak` responses since driver
-- start. Surfaced as the `extapi_nak_count` metric so an operator can
-- alert on any non-zero rate. NAKs are early signals of EMS-side
-- trouble (e.g. "no available ESOs detected in system" preceded the
-- 2026-05-27 brick by minutes).
local extapi_nak_count = 0
local extapi_ack_count = 0
-- -1 = "no snapshot yet" sentinel. host.millis() can legitimately
-- return 0 on the very first poll (sub-millisecond since startup), so
-- we can't use 0 to mean "never set".
local last_eso_counts_ms = -1
----------------------------------------------------------------------------
-- Helpers
----------------------------------------------------------------------------
-- Extract a value from Ferroamp's {"key": {"val": v}} structure.
-- Returns the raw val (string/number), or the field table if no "val" key.
local function extract_val(obj, key)
if not obj then return nil end
local field = obj[key]
if not field then return nil end
if type(field) == "table" and field.val ~= nil then
return field.val
end
return field
end
-- Sum L1+L2+L3 from a phase table {"L1":..,"L2":..,"L3":..}, or return scalar.
-- Also handles numeric arrays for backwards compatibility.
local function sum_phases(val)
if val == nil then return 0 end
if type(val) == "number" then return val end
if type(val) == "string" then return tonumber(val) or 0 end
if type(val) == "table" then
-- Try named keys first (current Ferroamp format)
if val.L1 or val.L2 or val.L3 then
return (tonumber(val.L1) or 0) + (tonumber(val.L2) or 0) + (tonumber(val.L3) or 0)
end
-- Fall back to numeric array
local s = 0
for _, v in ipairs(val) do
s = s + (tonumber(v) or 0)
end
return s
end
return 0
end
-- Get a specific phase value from {"L1":..,"L2":..,"L3":..} or array [1,2,3].
local function phase_val(val, phase)
if val == nil then return 0 end
if type(val) ~= "table" then return 0 end
-- Named key (e.g. "L1")
if val[phase] then return tonumber(val[phase]) or 0 end
-- Numeric index fallback (L1=1, L2=2, L3=3)
local idx = ({L1=1, L2=2, L3=3})[phase]
if idx and val[idx] then return tonumber(val[idx]) or 0 end
return 0
end
-- Convert Ferroamp mJ counter to Wh
local function mj_to_wh(mj_val)
local mj = tonumber(mj_val) or 0
return mj / 3600000
end
-- Prefer the primary topic value, but fall back to the role-specific topic
-- when the primary is missing or reports zero while the fallback has a real
-- magnitude. Some EnergyHub payloads keep pbat/ppv useful on ESO/SSO even
-- when ehub's summary field is zeroed.
local function choose_power(primary, fallback)
local p = tonumber(primary)
local f = tonumber(fallback)
if p ~= nil and math.abs(p) > 0.5 then return p end
if f ~= nil and math.abs(f) > 0.5 then return f end
if p ~= nil then return p end
return f
end
local function eso_battery_power(data)
if not data then return nil end
local ubat = tonumber(extract_val(data, "ubat"))
local ibat = tonumber(extract_val(data, "ibat"))
if ubat == nil or ibat == nil then return nil end
return ubat * ibat
end
-- Returns the id of an ESO payload, or "_default_" when the firmware
-- omits the `id` field. The synthetic key keeps single-ESO sims /
-- old firmware on the same code path as a 1-entry map.
local function eso_id_of(data)
local id = extract_val(data, "id")
if id == nil or id == "" then return "_default_" end
return tostring(id)
end
local function sso_power(data)
if not data then return nil end
local ppv = extract_val(data, "ppv")
if ppv ~= nil then return tonumber(ppv) end
-- The SSO topic does not publish ppv in all External API versions.
-- It does publish string voltage/current; use their product as a
-- measured-string fallback. Some firmware reports PV voltage in kV
-- below 10, so normalize that shape back to volts.
local upv = tonumber(extract_val(data, "upv"))
local ipv = tonumber(extract_val(data, "ipv"))
if upv == nil or ipv == nil then return nil end
local scale = math.abs(upv) < 10 and 1000 or 1
return upv * scale * ipv
end
local function publish_auto(trans_id)
local err = host.mqtt_publish("extapi/control/request",
string.format('{"transId":"%s","cmd":{"name":"auto"}}', trans_id))
if not err then last_control_mode = "auto" end
return err
end
-- Force the EnergyHub to hold the battery at 0 W instead of handing
-- control back to autonomous self-consumption. `auto` reads the
-- house load and discharges to cover it, which silently overrides
-- any planner slot that wants the battery idle so PV surplus can
-- export. `discharge` with arg=0 keeps the inverter in forced mode
-- but locked at zero — equivalent to Sungrow's forced-idle path.
local function publish_idle(trans_id)
local err = host.mqtt_publish("extapi/control/request",
string.format('{"transId":"%s","cmd":{"name":"discharge","arg":0}}', trans_id))
if not err then last_control_mode = "idle" end
return err
end
----------------------------------------------------------------------------
-- Driver interface
----------------------------------------------------------------------------
function driver_init(config)
host.set_make("Ferroamp")
-- Honour the `skip_battery` config knob if set — the driver stays
-- otherwise unchanged, but host.emit("battery", …) is skipped so
-- the rest of the stack (dashboard, models, planner) sees no
-- battery capability from this instance.
if config and config.skip_battery then
SKIP_BATTERY = true
host.log("info", "Ferroamp: skip_battery=true — battery emission disabled")
end
-- Per-ESO capacities for the weighted-SoC aggregation. We accept
-- whatever map the YAML hands us; ids are coerced to strings so a
-- user writing them bare (no quotes) still hits the lookup. Values
-- below 0.1 kWh are ignored — almost certainly a typo, and a tiny
-- weight near zero distorts the weighted mean.
if config and config.eso_capacity_kwh then
local n = 0
for k, v in pairs(config.eso_capacity_kwh) do
local kwh = tonumber(v)
if kwh and kwh >= 0.1 then
ESO_CAPACITY_KWH[tostring(k)] = kwh
n = n + 1
end
end
if n > 0 then
host.log("info", "Ferroamp: loaded capacity weights for " .. n .. " ESO(s) — bat_soc will be capacity-weighted")
end
end
-- Per-driver SoC bounds — operator override for the file-scope
-- DISCHARGE_FLOOR_SOC and CHARGE_CEIL_SOC defaults. Lets sites
-- with different chemistry / longevity preferences tune the
-- window without forking the driver. Ferroamp's own BMS still
-- protects against overcharge / deep discharge regardless of
-- what we set here.
if config and config.charge_ceil_soc ~= nil then
local v = tonumber(config.charge_ceil_soc)
if v and v > 0 and v <= 1.0 then
CHARGE_CEIL_SOC = v
host.log("info", string.format(
"Ferroamp: CHARGE_CEIL_SOC = %.3f (from config)", v))
else
host.log("warn", string.format(
"Ferroamp: charge_ceil_soc=%s ignored (must be 0 < v <= 1)",
tostring(config.charge_ceil_soc)))
end
end
if config and config.discharge_floor_soc ~= nil then
local v = tonumber(config.discharge_floor_soc)
if v and v >= 0 and v < 1.0 then
DISCHARGE_FLOOR_SOC = v
host.log("info", string.format(
"Ferroamp: DISCHARGE_FLOOR_SOC = %.3f (from config)", v))
else
host.log("warn", string.format(
"Ferroamp: discharge_floor_soc=%s ignored (must be 0 <= v < 1)",
tostring(config.discharge_floor_soc)))
end
end
if CHARGE_CEIL_SOC <= DISCHARGE_FLOOR_SOC then
host.log("warn", string.format(
"Ferroamp: CHARGE_CEIL_SOC (%.3f) <= DISCHARGE_FLOOR_SOC (%.3f) — usable charge window is empty",
CHARGE_CEIL_SOC, DISCHARGE_FLOOR_SOC))
end
-- pplim release watts: see the file-scope PPLIM_RELEASE_W comment for
-- why this matters (the 2026-05-27 sticky-pplim incident). Operators
-- who use supports_pv_curtail=true SHOULD set this to the SSO nominal
-- max so curtail_disable safely publishes a release. Leaving it 0
-- means "no release published" — safe default, but the operator must
-- manually clear pplim from the Ferroamp portal after curtail ends.
if config and config.pplim_release_w ~= nil then
local v = tonumber(config.pplim_release_w)
if v and v > 0 then
PPLIM_RELEASE_W = math.floor(v)
host.log("info", string.format(
"Ferroamp: PPLIM_RELEASE_W = %d (from config)", PPLIM_RELEASE_W))
else
host.log("warn", string.format(
"Ferroamp: pplim_release_w=%s ignored (must be > 0)",
tostring(config.pplim_release_w)))
end
end
-- Subscribe to telemetry topics
host.mqtt_subscribe("extapi/data/ehub")
host.mqtt_subscribe("extapi/data/eso")
host.mqtt_subscribe("extapi/data/sso")
-- Subscribe to the EMS-side response channel for every command we
-- publish. We parse `{"status":"ack|nak", ...}` from each message
-- and count NAKs in a metric for operator alerting. The 2026-05-27
-- brick was preceded by minutes of `{"status":"nak","msg":"no
-- available ESOs detected in system"}` that we couldn't see at the
-- time because the driver subscribed to the wrong topic. Older
-- code used "extapi/result"; the actual response topic on the
-- firmwares we've tested is "extapi/control/response".
host.mqtt_subscribe("extapi/control/response")
-- Query API version to verify connectivity and external API access
local version_cmd = '{"transId":"init","cmd":{"name":"extapiversion"}}'
host.mqtt_publish("extapi/control/request", version_cmd)
host.log("info", "Ferroamp: sent extapiversion query")
-- Ensure we start in auto mode (clean state)
publish_auto("init")
host.log("info", "Ferroamp: set auto mode on init")
end
function driver_poll()
local now = host.millis()
local messages = host.mqtt_messages()
if not messages then messages = {} end
-- Process incoming messages and stamp arrival time per topic
for _, msg in ipairs(messages) do
local ok, data = pcall(host.json_decode, msg.payload)
if ok and data then
if msg.topic == "extapi/data/ehub" then
ehub_data = data; ehub_ts = now
-- Latch ehub.soc whenever it's present (it's only emitted
-- on a slow cadence, ~1 in 9 messages on the firmware we
-- tested). Once latched, it stays the authoritative SoC
-- until EHUB_SOC_STALE_MS elapses without a refresh.
local soc_field = data["soc"]
if soc_field then
local v = type(soc_field) == "table" and soc_field.val or soc_field
local n = tonumber(v)
if n then
if n > 1 then n = n / 100 end
last_ehub_soc = n
last_ehub_soc_ts = now
end
end
elseif msg.topic == "extapi/data/eso" then
local eid = eso_id_of(data)
eso_data_by_id[eid] = data
eso_ts_by_id[eid] = now
elseif msg.topic == "extapi/data/sso" then
sso_data = data; sso_ts = now
elseif msg.topic == "extapi/control/response" then
-- Track EMS-side ack/nak counters per published cmd.
-- A NAK is the canary for trouble (`"no available ESOs
-- detected in system"` preceded the 2026-05-27 brick by
-- minutes). Log every NAK so operators can correlate
-- with their command stream; surface the count as a
-- metric so ops dashboards can alert on rate.
local status = data["status"]
if status == "nak" then
extapi_nak_count = extapi_nak_count + 1
host.log("warn", string.format(
"Ferroamp: extapi NAK (transId=%s msg=%s)",
tostring(data["transId"] or "?"),
tostring(data["msg"] or "?")))
elseif status == "ack" then
extapi_ack_count = extapi_ack_count + 1
end
end
end
end
host.emit_metric("extapi_nak_count", extapi_nak_count)
host.emit_metric("extapi_ack_count", extapi_ack_count)
-- Drop stale caches so the rest of the poll falls through and
-- the watchdog catches us when the EnergyHub stops publishing.
-- Per-topic so a partial outage (e.g. eso lags but ehub flows)
-- still lets the live channels through.
if ehub_data and (now - ehub_ts) > STALE_AFTER_MS then
host.log("warn", "Ferroamp: ehub stale (" .. (now - ehub_ts) .. " ms) — dropping cache")
ehub_data = nil
last_ehub_soc = nil
last_ehub_soc_ts = 0
end
-- Evict per-ESO entries individually so one silent ESO does not
-- drag the others' contribution out of the aggregate. The freshest
-- ESO timestamp is then used for the topic-level age metric.
local eso_ts = 0
for eid, ts in pairs(eso_ts_by_id) do
if (now - ts) > STALE_AFTER_MS then
eso_data_by_id[eid] = nil
eso_ts_by_id[eid] = nil
elseif ts > eso_ts then
eso_ts = ts
end
end
if sso_data and (now - sso_ts) > STALE_AFTER_MS then
sso_data = nil
end
-- Diagnostics: per-topic age into the long-format TS DB so
-- operators can see partial outages directly in the metric
-- browser. Reported as "0" when never seen yet (ts = 0).
host.emit_metric("ehub_age_ms", ehub_ts == 0 and 0 or (now - ehub_ts))
host.emit_metric("eso_age_ms", eso_ts == 0 and 0 or (now - eso_ts))
host.emit_metric("sso_age_ms", sso_ts == 0 and 0 or (now - sso_ts))
--------------------------------------------------------------------------
-- Meter (grid connection point)
--------------------------------------------------------------------------
if ehub_data then
local pext = extract_val(ehub_data, "pext") -- per-phase grid power (W)
local gridfreq = extract_val(ehub_data, "gridfreq") -- grid frequency (Hz)
local ul = extract_val(ehub_data, "ul") -- per-phase voltage (V)
-- iext = per-phase GRID current at the service-entrance CTs, the
-- same source pext is derived from. NOT il (which is inverter AC
-- current and misses any load not routed through the Ferroamp
-- inverter, e.g. an EV charger on a separate breaker — that mix
-- made the fuse bars under-read by the EV share of total import).
local iext = extract_val(ehub_data, "iext") -- per-phase grid current (A)
-- 3-phase energy totals in mJ
local wextconsq3p = extract_val(ehub_data, "wextconsq3p") -- total import mJ
local wextprodq3p = extract_val(ehub_data, "wextprodq3p") -- total export mJ
local meter = {}
-- Grid power: negative = exporting, positive = importing
meter.w = sum_phases(pext)
meter.l1_w = phase_val(pext, "L1")
meter.l2_w = phase_val(pext, "L2")
meter.l3_w = phase_val(pext, "L3")
-- Grid frequency
if gridfreq then
meter.hz = tonumber(gridfreq) or 0
end
-- Per-phase voltage
meter.l1_v = phase_val(ul, "L1")
meter.l2_v = phase_val(ul, "L2")
meter.l3_v = phase_val(ul, "L3")
-- Per-phase grid current (from service-entrance CTs, consistent
-- with pext above — previously read il by mistake, which is
-- inverter AC current).
meter.l1_a = phase_val(iext, "L1")
meter.l2_a = phase_val(iext, "L2")
meter.l3_a = phase_val(iext, "L3")
-- Energy counters (mJ → Wh)
if wextconsq3p then
meter.import_wh = mj_to_wh(wextconsq3p)
end
if wextprodq3p then
meter.export_wh = mj_to_wh(wextprodq3p)
end
host.emit("meter", meter)
-- Diagnostics: long-format TS DB
if meter.l1_w then host.emit_metric("meter_l1_w", meter.l1_w) end
if meter.l2_w then host.emit_metric("meter_l2_w", meter.l2_w) end
if meter.l3_w then host.emit_metric("meter_l3_w", meter.l3_w) end
if meter.l1_v then host.emit_metric("meter_l1_v", meter.l1_v) end
if meter.l2_v then host.emit_metric("meter_l2_v", meter.l2_v) end
if meter.l3_v then host.emit_metric("meter_l3_v", meter.l3_v) end
if meter.l1_a then host.emit_metric("meter_l1_a", meter.l1_a) end
if meter.l2_a then host.emit_metric("meter_l2_a", meter.l2_a) end
if meter.l3_a then host.emit_metric("meter_l3_a", meter.l3_a) end
if meter.hz then host.emit_metric("grid_hz", meter.hz) end
local state = extract_val(ehub_data, "state")
if state then
local sn = tonumber(state) or 0
host.emit_metric("ehub_state", sn)
-- EnergyHub "Fault Mode" = ehub.state bit 15 (0x8000) set (e.g.
-- 0x8030); normal operating states (0x1001 / 0x1101) don't have it.
-- In Fault Mode the hub opens its PV + battery relays — it keeps
-- publishing telemetry but cannot actuate. Flag a device fault so
-- the dispatcher + MPC exclude it instead of commanding a dead
-- battery (whose un-delivered power would silently become grid
-- import) and so the dashboard shows "fault", not "ok". Cleared
-- automatically when the hub recovers (state bit 15 clears).
-- (Lua 5.1 has no bitops; isolate bit 15 arithmetically.)
local faultMode = (math.floor(sn / 32768) % 2) == 1
host.set_device_fault(faultMode,
faultMode and ("EnergyHub Fault Mode (ehub state " .. tostring(sn) .. ")") or "")
end
end
--------------------------------------------------------------------------
-- PV (solar generation)
--------------------------------------------------------------------------
if ehub_data or sso_data then
local ppv = choose_power(extract_val(ehub_data, "ppv"), sso_power(sso_data))
if ppv then
-- Negate: Ferroamp reports PV as positive, convention requires negative
host.emit("pv", { w = -ppv })
end
end
--------------------------------------------------------------------------
-- Battery (aggregated across N ESOs)
--------------------------------------------------------------------------
if not SKIP_BATTERY and (ehub_data or next(eso_data_by_id)) then
-- Walk every live ESO once and accumulate the aggregate.
-- Power is summed (parallel DC strings each push their own
-- current onto the inverter); voltage / SoC / dc-link / temp
-- are averaged because cells across ESOs run in lock-step in
-- a healthy cluster and we want a single representative number
-- for the dashboard. Cumulative Wh counters are summed so the
-- battery's lifetime production/consumption reflects all units.
local pbat_sum = 0
local pbat_has_any = false
local v_sum, v_n = 0, 0
local a_sum, a_n = 0, 0
local soc_sum, soc_n = 0, 0
local soc_wsum, cap_sum = 0, 0 -- capacity-weighted SoC accumulators
local udc_sum, udc_n = 0, 0
local wprod_sum, wprod_n = 0, 0
local wcons_sum, wcons_n = 0, 0
local relay_worst, fault_worst = nil, nil
local n_eso = 0
local n_discharge_capable, n_charge_capable = 0, 0
local eso_pbat = {} -- per-ESO ubat*ibat (+=discharge, -=charge) for the active detector
-- Fallback weight for ESOs not listed in ESO_CAPACITY_KWH: the
-- mean of the configured weights. Picking the mean (not 0, not 1)
-- means a partial config doesn't silently exclude unknown units
-- from the weighted aggregate. If the user lists zero ESOs we
-- never enter the weighted branch — `cap_sum > 0` gates it.
local default_cap = nil
do
local s, n = 0, 0
for _, kwh in pairs(ESO_CAPACITY_KWH) do s = s + kwh; n = n + 1 end
if n > 0 then default_cap = s / n end
end
for id, d in pairs(eso_data_by_id) do
n_eso = n_eso + 1
local u = tonumber(extract_val(d, "ubat"))
local i = tonumber(extract_val(d, "ibat"))
if u and i then
pbat_sum = pbat_sum + (u * i)
pbat_has_any = true
eso_pbat[#eso_pbat + 1] = u * i -- +discharge / -charge (per-ESO)
end
if u then v_sum = v_sum + u; v_n = v_n + 1 end
if i then a_sum = a_sum + i; a_n = a_n + 1 end
local soc = tonumber(extract_val(d, "soc"))
if soc then
if soc > 1 then soc = soc / 100 end
soc_sum = soc_sum + soc; soc_n = soc_n + 1
local cap = ESO_CAPACITY_KWH[tostring(id)] or default_cap
if cap then
soc_wsum = soc_wsum + soc * cap
cap_sum = cap_sum + cap
end
if soc >= DISCHARGE_FLOOR_SOC then
n_discharge_capable = n_discharge_capable + 1
end
-- SoC-capable counts are used only for the "every unit
-- floored/ceilinged → idle" guard in driver_command. The
-- magnitude up-scale is handled by the delivery-ratio loop
-- (see note near MAX_DISPATCH_SCALE), not a per-unit vote.
if soc <= CHARGE_CEIL_SOC then
n_charge_capable = n_charge_capable + 1
end
else
-- Missing SoC: treat as capable in both directions. The
-- alternative (skip from capable counts but keep in
-- n_eso) inflates scale and overdelivers; counting as
-- capable only under-scales by one slot in the rare
-- transient where an ESO is genuinely floored AND its
-- soc field went missing in the same payload.
n_discharge_capable = n_discharge_capable + 1
n_charge_capable = n_charge_capable + 1
end
local udc = tonumber(extract_val(d, "udc"))
if udc then udc_sum = udc_sum + udc; udc_n = udc_n + 1 end
local wp = tonumber(extract_val(d, "wbatprod"))
if wp then wprod_sum = wprod_sum + wp; wprod_n = wprod_n + 1 end
local wc = tonumber(extract_val(d, "wbatcons"))
if wc then wcons_sum = wcons_sum + wc; wcons_n = wcons_n + 1 end
-- relaystatus + faultcode: worst-of so a single faulted
-- ESO surfaces in the diagnostic, instead of being averaged
-- away by its still-healthy peers.
local relay = tonumber(extract_val(d, "relaystatus"))
if relay then relay_worst = math.max(relay_worst or 0, relay) end
local fault = tonumber(extract_val(d, "faultcode"))
if fault then fault_worst = math.max(fault_worst or 0, fault) end
end
local battery = nil
if pbat_has_any then
-- Prefer per-ESO ubat*ibat because the cell-monitor numbers
-- update at the ESO's own publish cadence and don't get
-- rounded through ehub's aggregate. Ferroamp convention:
-- positive pbat = discharging, negate for site convention
-- (positive = charging).
battery = { w = -pbat_sum }
elseif ehub_data then
-- No live per-ESO measurement: fall back to ehub.pbat
-- (also positive = discharging on Ferroamp's side).
local ehub_pbat = tonumber(extract_val(ehub_data, "pbat"))
if ehub_pbat then battery = { w = -ehub_pbat } end
end
-- Per-ESO delivery detector: count how many units actually delivered
-- power in the direction of our last on-wire setpoint. A unit at its
-- SoC limit (full on charge, empty on discharge) delivers ~0 and is
-- counted out; driver_command then scales N_eso/N_active so the
-- delivering units cover the stuck unit's even share. Measured from
-- per-ESO ubat*ibat (+discharge / -charge), not SoC, so a unit just
-- above the floor that still won't dispatch is correctly excluded.
-- A unit counts as "active" only if it carries at least half its 1/N
-- share of the on-wire setpoint. Only measured above the noise floor;
-- a fresh dispatch / direction flip / idle clears the counts so the
-- next command starts at 1.0x and re-converges within a tick.
if (last_control_mode == "charge" or last_control_mode == "discharge")
and last_commanded_w >= SCALE_FB_MIN_W and n_eso > 0 and #eso_pbat > 0 then
-- Threshold = half a unit's 1/N share of the COMMANDED power (not
-- the scaled on-wire value): a delivering unit carries >= 1/N of
-- commanded (more once scaled), comfortably above this, while a
-- stuck unit reads ~0. Keying off commanded keeps the threshold
-- fixed as scale climbs, so it can't exclude real deliverers.
local thresh = ACTIVE_SHARE_FRAC * (last_commanded_w / n_eso)
local nc, nd = 0, 0
for _, p in ipairs(eso_pbat) do
if p <= -thresh then nc = nc + 1 end -- charging at/above share
if p >= thresh then nd = nd + 1 end -- discharging at/above share
end
last_eso_active_charge = nc
last_eso_active_discharge = nd
elseif last_control_mode == "idle" or last_control_mode == "auto" then
last_eso_active_charge = nil
last_eso_active_discharge = nil
end
host.emit_metric("eso_active_charge", last_eso_active_charge or 0)
host.emit_metric("eso_active_discharge", last_eso_active_discharge or 0)
if battery then
if v_n > 0 then battery.v = v_sum / v_n end
if a_n > 0 then battery.a = a_sum end -- sum, not avg: parallel currents add
-- SoC selection on multi-ESO sites. Priority:
-- 1. ehub.soc — Ferroamp's own system SoC, the same number
-- their mobile app shows. Cached because it's only
-- published on a slow cadence (~1 in 9 ehub messages on
-- the firmware we tested). When fresh this is the
-- authoritative reading; matches the app to within
-- rounding on heterogeneous clusters.
-- 2. Capacity-weighted mean — when ehub.soc is stale or
-- absent and the user has configured per-ESO capacities
-- (eso_capacity_kwh in YAML). The physically-correct
-- total-stored / total-capacity number.
-- 3. Arithmetic mean of per-ESO soc — historical behaviour,
-- always emitted as bat_soc_eso_mean for observability.
local soc_eso_mean
if soc_n > 0 then soc_eso_mean = soc_sum / soc_n end
local soc_weighted
if cap_sum > 0 then soc_weighted = soc_wsum / cap_sum end
local soc_ehub
if last_ehub_soc ~= nil and (now - last_ehub_soc_ts) <= EHUB_SOC_STALE_MS then
soc_ehub = last_ehub_soc
end
if soc_ehub then
battery.soc = soc_ehub
elseif soc_weighted then
battery.soc = soc_weighted
elseif soc_eso_mean then
battery.soc = soc_eso_mean
end
if wprod_n > 0 then battery.discharge_wh = mj_to_wh(wprod_sum) end
if wcons_n > 0 then battery.charge_wh = mj_to_wh(wcons_sum) end
-- Per-direction capability for the dispatcher's reallocation
-- (docs/.../capability-aware-battery-reallocation). Mirrors the
-- eso_*_capable counts that already drive our own EHub dispatch
-- scaling: when every ESO is floored/ceilinged the pack can't
-- move that way this cycle, so the dispatcher should hand its
-- share to a capable sibling instead of commanding a setpoint
-- driver_command would only idle. Absent on legacy fields →
-- the dispatcher assumes capable, so this is purely additive.
battery.discharge_capable = n_discharge_capable > 0
battery.charge_capable = n_charge_capable > 0
host.emit("battery", battery)
if battery.v then host.emit_metric("battery_dc_v", battery.v) end
if battery.a then host.emit_metric("battery_dc_a", battery.a) end
if soc_ehub then host.emit_metric("bat_soc_ehub", soc_ehub) end
if soc_eso_mean then host.emit_metric("bat_soc_eso_mean", soc_eso_mean) end
if soc_weighted then host.emit_metric("bat_soc_weighted", soc_weighted) end
if n_eso > 0 then
host.emit_metric("eso_count", n_eso)
host.emit_metric("eso_discharge_capable", n_discharge_capable)
host.emit_metric("eso_charge_capable", n_charge_capable)
if udc_n > 0 then host.emit_metric("eso_dc_link_v", udc_sum / udc_n) end
if relay_worst ~= nil then host.emit_metric("eso_relaystatus", relay_worst) end
if fault_worst ~= nil then host.emit_metric("eso_faultcode", fault_worst) end
end
end
-- Publish counts to module state so driver_command can scale.
-- Stamp the timestamp too — driver_command must refuse to scale
-- on stale data, otherwise a partial broker stall (some ESOs
-- evicted, others not) leaves an inflated scale persisting
-- between polls.
last_eso_count = n_eso
last_eso_discharge_capable = n_discharge_capable
last_eso_charge_capable = n_charge_capable
last_eso_counts_ms = now
end
if sso_data then
local sso_udc = extract_val(sso_data, "udc")
if sso_udc then host.emit_metric("sso_dc_link_v", tonumber(sso_udc) or 0) end
local sso_upv = extract_val(sso_data, "upv")
local upv_n = tonumber(sso_upv) or 0
if sso_upv then host.emit_metric("sso_pv_v", upv_n) end
local sso_ipv = extract_val(sso_data, "ipv")
local ipv_n = tonumber(sso_ipv) or 0
if sso_ipv then host.emit_metric("sso_pv_a", ipv_n) end
local sso_relay = extract_val(sso_data, "relaystatus")
local relay_n = tonumber(sso_relay) or 0
if sso_relay then host.emit_metric("sso_relaystatus", relay_n) end
local sso_fault = extract_val(sso_data, "faultcode")
local fault_n = tonumber(sso_fault) or 0
if sso_fault then host.emit_metric("sso_faultcode", fault_n) end
-- Stuck-pplim self-healing watchdog. The 2026-05-27 incident
-- left the SSO at upv≈500V + ipv=0 + faultcode=0 + relay=1
-- (paneler aktiva, ingen MPPT, ingen hårdvarufel) — the
-- signature of a sticky `pplim arg=0` lock. Recovery via portal
-- took 30+ minutes. If the operator has opted in by setting
-- `pplim_release_w`, the driver now detects the signature and
-- auto-publishes a release (`pplim arg=PPLIM_RELEASE_W`) after
-- STUCK_PV_AFTER_MS continuous, throttled by a cooldown so a
-- persistent issue can't loop us into command-spam.
local stuck = (upv_n > STUCK_PV_DC_V_THRESHOLD)
and (ipv_n == 0)
and (fault_n == 0)
and (relay_n == 1)
if stuck then
if stuck_pv_since_ms < 0 then
stuck_pv_since_ms = now
elseif (now - stuck_pv_since_ms) > STUCK_PV_AFTER_MS then
local cool_ok = stuck_pv_last_recovery_ms < 0
or (now - stuck_pv_last_recovery_ms) > STUCK_PV_RECOVERY_COOLDOWN_MS
if PPLIM_RELEASE_W > 0 and cool_ok then
local payload = string.format(
'{"transId":"stuck-pv-recover","cmd":{"name":"pplim","arg":%d}}',
PPLIM_RELEASE_W)
local err = host.mqtt_publish("extapi/control/request", payload)
if not err then
stuck_pv_last_recovery_ms = now
stuck_pv_recovery_count = stuck_pv_recovery_count + 1
host.log("warn", string.format(
"Ferroamp: stuck-pplim detected (upv=%.1fV, ipv=0A for %d min) — auto-published pplim arg=%d to recover",
upv_n, math.floor((now - stuck_pv_since_ms) / 60000), PPLIM_RELEASE_W))
end
elseif PPLIM_RELEASE_W <= 0 and cool_ok then
-- Log-only path: operator hasn't opted in. Reuse the
-- cooldown so we don't spam every poll.
stuck_pv_last_recovery_ms = now
host.log("warn", string.format(
"Ferroamp: stuck-pplim signature for %d min (upv=%.1fV, ipv=0A) — set config.pplim_release_w to enable auto-recovery",
math.floor((now - stuck_pv_since_ms) / 60000), upv_n))
end
end
else
stuck_pv_since_ms = -1
end
host.emit_metric("stuck_pv_recovery_count", stuck_pv_recovery_count)
end
return 1000
end
----------------------------------------------------------------------------
-- Control
----------------------------------------------------------------------------
-- Control: Ferroamp External API
-- Reference: https://github.com/henricm/ha-ferroamp
-- Topic: extapi/control/request
-- Commands:
-- {"transId":"...","cmd":{"name":"charge","arg":<watts>}} — force charge (arg always positive)
-- {"transId":"...","cmd":{"name":"discharge","arg":<watts>}} — force discharge (arg always positive)
-- {"transId":"...","cmd":{"name":"auto"}} — return to auto mode
-- EMS convention: positive power_w = charge, negative = discharge
function driver_command(action, power_w, cmd)
if action == "init" then
return true
elseif action == "battery" then
local now = host.millis()
local tid = "ems-" .. tostring(now)
-- Up-scale the on-wire setpoint so the units that ARE delivering cover
-- the even share of any unit stuck at 0 (the EHub splits the setpoint
-- evenly across all ESOs). Inactive units are detected by actual power
-- delivery, not SoC (see the active-detector note near
-- MAX_DISPATCH_SCALE). The SoC-capable count is used ONLY to detect
-- "every unit floored/ceilinged → idle". We act only when the per-ESO
-- snapshot is fresh (<= STALE_AFTER_MS) so a broker stall can't scale
-- off a stale snapshot.
--
-- Reset the active counts on a direction flip so each direction
-- re-converges from 1.0x instead of inheriting the other's count.
if (power_w > 0 and last_control_mode ~= "charge") or
(power_w < 0 and last_control_mode ~= "discharge") then
last_eso_active_charge = nil
last_eso_active_discharge = nil
end
local on_wire_w = power_w
local scale = 1.0
local fresh = last_eso_counts_ms >= 0
and (now - last_eso_counts_ms) <= STALE_AFTER_MS
if fresh and last_eso_count > 0 and power_w ~= 0 then
local capable
if power_w > 0 then capable = last_eso_charge_capable
else capable = last_eso_discharge_capable end
if capable == 0 then
-- Every unit floored/ceilinged for this direction — publish
-- idle rather than command something nothing can honour.
host.log("warn", string.format(
"Ferroamp: all %d ESOs at SoC limit for requested %d W — idling",
last_eso_count, math.floor(power_w)))
host.emit_metric("eso_dispatch_scale_x1000", 0)
host.emit_metric("eso_dispatch_commanded_w", 0)
last_on_wire_w = 0
last_commanded_w = 0
-- Re-publish every tick (see the zero branch below): a
-- one-shot idle lets the EHub's forced mode expire and
-- revert to autonomous charging from grid.
return publish_idle(tid)
end
-- Scale by N_eso / N_active in the commanded direction, where
-- N_active is how many units actually DELIVERED power last tick
-- (measured, not SoC). Same detector both directions: a full unit
-- on charge and an empty unit on discharge both read "0 delivered"
-- → excluded → the rest cover their share. The active units split
-- the commanded power exactly, so the pack delivers the commanded
-- total and never more (scale 1.0 when all deliver). nil active
-- (fresh dispatch / direction flip / sub-noise command) → 1.0x and
-- re-measure next tick.
local active
if power_w > 0 then active = last_eso_active_charge
else active = last_eso_active_discharge end
if active ~= nil and active > 0 and active < last_eso_count then
scale = last_eso_count / active
if scale > MAX_DISPATCH_SCALE then scale = MAX_DISPATCH_SCALE end
end
on_wire_w = power_w * scale
end
last_on_wire_w = math.abs(on_wire_w) -- scaled setpoint actually sent
last_commanded_w = math.abs(power_w) -- dispatch command — the active threshold base
host.emit_metric("eso_dispatch_scale_x1000", math.floor(scale * 1000 + 0.5))
host.emit_metric("eso_dispatch_commanded_w", math.floor(power_w))
if power_w > 0 then
-- Charge: use "charge" command with positive watts