Notifications
You must be signed in to change notification settings - Fork 6
Expand file tree
/
Copy pathfronius.lua
More file actions
312 lines (267 loc) · 12.1 KB
/
Copy pathfronius.lua
File metadata and controls
312 lines (267 loc) · 12.1 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
-- fronius.lua
-- Fronius Symo / Primo GEN24 hybrid inverter driver
-- Emits: PV, Battery, Meter
-- Protocol: Modbus TCP (SunSpec), ALL HOLDING registers
-- Ported from sourceful-hugin/device-support/drivers/lua/fronius.lua
-- Port notes (v2.1 API drift vs hugin):
-- host.log(msg) → host.log("info", msg)
-- host.decode_u32/i32 → _be variants
-- host.decode_f32 → inline IEEE-754 (two u16, big-endian words)
-- host.scale(v, sf) → local apply_sf(v, sf)
DRIVER = {
host_api_min = 1,
host_api_max = 1,
id = "fronius",
name = "Fronius GEN24",
manufacturer = "Fronius",
version = "1.0.0",
protocols = { "modbus" },
capabilities = { "pv", "battery" },
description = "Fronius Symo / Primo GEN24 hybrid inverters via Modbus TCP (SunSpec).",
homepage = "https://www.fronius.com",
authors = { "FTW contributors" },
tested_models = { "Symo GEN24", "Primo GEN24" },
verification_status = "experimental",
verification_notes = "Ported from a reference implementation. Not yet verified against live hardware on a FTW site.",
connection_defaults = {
port = 502,
unit_id = 1,
},
}
--
-- Register conventions:
-- All registers read as FC 0x03 (holding).
-- Inverter scalar values (AC power, frequency, DC power, per-phase V/A)
-- are SunSpec IEEE 754 float32, two consecutive u16 registers, big-endian
-- word order (high word first).
-- MPPT, battery, and rated-power values are u16/i16 raw + a signed
-- int16 scale factor in a separate register.
--
-- Sign convention (site/EMS):
-- meter.w : positive = importing from grid, negative = exporting
-- pv.w : always <= 0 (generation pushes to site)
-- battery.w: positive = charging (into battery), negative = discharging
PROTOCOL = "modbus"
local sn_read = false
----------------------------------------------------------------------------
-- Local decoders (replace host.decode_f32 / host.scale from hugin v1.x)
----------------------------------------------------------------------------
-- Apply a SunSpec int16 scale factor: value * 10^sf.
-- sf is typically in the range [-3, 3]; split on sign to avoid 10^(-n)
-- rounding quirks.
local function apply_sf(v, sf)
if sf >= 0 then
return v * (10 ^ sf)
else
return v / (10 ^ -sf)
end
end
-- Decode IEEE 754 single-precision float from two u16 registers,
-- big-endian word order: hi = first register, lo = second.
-- Treats NaN / ±Inf (SunSpec "not implemented" sentinel 0x7FC00000) as 0.
local function decode_f32_be(hi, lo)
local bits = (hi % 0x10000) * 0x10000 + (lo % 0x10000)
if bits == 0 then return 0 end
local sign = (bits >= 0x80000000) and -1 or 1
local exp = math.floor(bits / 0x800000) % 0x100
local frac = bits % 0x800000
if exp == 0xFF then return 0 end
if exp == 0 then return sign * frac * 2 ^ -149 end
return sign * (1 + frac / 0x800000) * 2 ^ (exp - 127)
end
-- Turn a Lua array of u16s into an ASCII string, trimming NULs and spaces.
local function regs_to_string(regs, count)
if not regs then return "" end
local s = ""
for i = 1, count do
local r = regs[i] or 0
local hi = math.floor(r / 256)
local lo = r % 256
if hi > 32 and hi < 127 then s = s .. string.char(hi) end
if lo > 32 and lo < 127 then s = s .. string.char(lo) end
end
return s
end
----------------------------------------------------------------------------
-- Initialization
----------------------------------------------------------------------------
function driver_init(config)
host.set_make("Fronius")
end
----------------------------------------------------------------------------
-- Telemetry polling
----------------------------------------------------------------------------
function driver_poll()
-- Read SunSpec Common block serial number once (40052, 16 regs = 32 chars).
-- Some gateways don't expose the common block; fall back silently.
if not sn_read then
local ok_sn, sn_regs = pcall(host.modbus_read, 40052, 16, "holding")
if ok_sn and sn_regs then
local sn = regs_to_string(sn_regs, 16)
if #sn > 0 then
host.set_sn(sn)
sn_read = true
end
end
end
-- ---------------------------------------------------------------- SFs
-- Scale factors live in separate i16 registers.
local rated_w_sf = 0
local ok_rwsf, rwsf_regs = pcall(host.modbus_read, 40135, 1, "holding")
if ok_rwsf and rwsf_regs then rated_w_sf = host.decode_i16(rwsf_regs[1]) end
local mppt_a_sf = 0
local ok_masf, masf_regs = pcall(host.modbus_read, 40265, 1, "holding")
if ok_masf and masf_regs then mppt_a_sf = host.decode_i16(masf_regs[1]) end
local mppt_v_sf = 0
local ok_mvsf, mvsf_regs = pcall(host.modbus_read, 40266, 1, "holding")
if ok_mvsf and mvsf_regs then mppt_v_sf = host.decode_i16(mvsf_regs[1]) end
local max_charge_sf = 0
local ok_mcsf, mcsf_regs = pcall(host.modbus_read, 40331, 1, "holding")
if ok_mcsf and mcsf_regs then max_charge_sf = host.decode_i16(mcsf_regs[1]) end
local soc_sf = 0
local ok_socsf, socsf_regs = pcall(host.modbus_read, 40335, 1, "holding")
if ok_socsf and socsf_regs then soc_sf = host.decode_i16(socsf_regs[1]) end
local bat_v_sf = 0
local ok_bvsf, bvsf_regs = pcall(host.modbus_read, 40337, 1, "holding")
if ok_bvsf and bvsf_regs then bat_v_sf = host.decode_i16(bvsf_regs[1]) end
local charge_rate_sf = 0
local ok_crsf, crsf_regs = pcall(host.modbus_read, 40338, 1, "holding")
if ok_crsf and crsf_regs then charge_rate_sf = host.decode_i16(crsf_regs[1]) end
-- ---------------------------------------------------------------- PV
-- Inverter/AC values are SunSpec F32 BE pairs.
local ac_w = 0
local ok_acw, acw_regs = pcall(host.modbus_read, 40091, 2, "holding")
if ok_acw and acw_regs then ac_w = decode_f32_be(acw_regs[1], acw_regs[2]) end
local hz = 0
local ok_hz, hz_regs = pcall(host.modbus_read, 40093, 2, "holding")
if ok_hz and hz_regs then hz = decode_f32_be(hz_regs[1], hz_regs[2]) end
local lifetime_wh = 0
local ok_le, le_regs = pcall(host.modbus_read, 40101, 2, "holding")
if ok_le and le_regs then lifetime_wh = decode_f32_be(le_regs[1], le_regs[2]) end
local dc_w = 0
local ok_dcw, dcw_regs = pcall(host.modbus_read, 40107, 2, "holding")
if ok_dcw and dcw_regs then dc_w = decode_f32_be(dcw_regs[1], dcw_regs[2]) end
local heatsink_c = 0
local ok_temp, temp_regs = pcall(host.modbus_read, 40111, 2, "holding")
if ok_temp and temp_regs then heatsink_c = decode_f32_be(temp_regs[1], temp_regs[2]) end
-- Rated W: 40134, U16 raw × 10^rated_w_sf
local rated_w = 0
local ok_rw, rw_regs = pcall(host.modbus_read, 40134, 1, "holding")
if ok_rw and rw_regs then rated_w = apply_sf(rw_regs[1], rated_w_sf) end
-- MPPT1 A/V: 40282-40283, U16 each
local mppt1_a, mppt1_v = 0, 0
local ok_m1, m1_regs = pcall(host.modbus_read, 40282, 2, "holding")
if ok_m1 and m1_regs then
mppt1_a = apply_sf(m1_regs[1], mppt_a_sf)
mppt1_v = apply_sf(m1_regs[2], mppt_v_sf)
end
-- MPPT2 A/V: 40302-40303, U16 each
local mppt2_a, mppt2_v = 0, 0
local ok_m2, m2_regs = pcall(host.modbus_read, 40302, 2, "holding")
if ok_m2 and m2_regs then
mppt2_a = apply_sf(m2_regs[1], mppt_a_sf)
mppt2_v = apply_sf(m2_regs[2], mppt_v_sf)
end
-- Per-phase AC current: 40073, 40075, 40077 (F32 BE pairs)
local l1_a, l2_a, l3_a = 0, 0, 0
local ok_l1a, l1a_regs = pcall(host.modbus_read, 40073, 2, "holding")
if ok_l1a and l1a_regs then l1_a = decode_f32_be(l1a_regs[1], l1a_regs[2]) end
local ok_l2a, l2a_regs = pcall(host.modbus_read, 40075, 2, "holding")
if ok_l2a and l2a_regs then l2_a = decode_f32_be(l2a_regs[1], l2a_regs[2]) end
local ok_l3a, l3a_regs = pcall(host.modbus_read, 40077, 2, "holding")
if ok_l3a and l3a_regs then l3_a = decode_f32_be(l3a_regs[1], l3a_regs[2]) end
-- Per-phase AC voltage: 40085, 40087, 40089 (F32 BE pairs)
local l1_v, l2_v, l3_v = 0, 0, 0
local ok_l1v, l1v_regs = pcall(host.modbus_read, 40085, 2, "holding")
if ok_l1v and l1v_regs then l1_v = decode_f32_be(l1v_regs[1], l1v_regs[2]) end
local ok_l2v, l2v_regs = pcall(host.modbus_read, 40087, 2, "holding")
if ok_l2v and l2v_regs then l2_v = decode_f32_be(l2v_regs[1], l2v_regs[2]) end
local ok_l3v, l3v_regs = pcall(host.modbus_read, 40089, 2, "holding")
if ok_l3v and l3v_regs then l3_v = decode_f32_be(l3v_regs[1], l3v_regs[2]) end
-- Emit PV (dc_w magnitude → negative for generation, per site convention)
host.emit("pv", {
w = -dc_w,
mppt1_v = mppt1_v,
mppt1_a = mppt1_a,
mppt2_v = mppt2_v,
mppt2_a = mppt2_a,
lifetime_wh = lifetime_wh,
temp_c = heatsink_c,
rated_w = rated_w,
})
-- Diagnostics: long-format TS DB
host.emit_metric("pv_mppt1_v", mppt1_v)
host.emit_metric("pv_mppt1_a", mppt1_a)
host.emit_metric("pv_mppt2_v", mppt2_v)
host.emit_metric("pv_mppt2_a", mppt2_a)
host.emit_metric("inverter_temp_c", heatsink_c)
host.emit_metric("grid_hz", hz)
-- ----------------------------------------------------------- Battery
-- Max charge power: 40315, U16 raw × 10^max_charge_sf
local max_charge_w = 0
local ok_maxchg, maxchg_regs = pcall(host.modbus_read, 40315, 1, "holding")
if ok_maxchg and maxchg_regs then
max_charge_w = apply_sf(maxchg_regs[1], max_charge_sf)
end
-- Battery SoC: 40321, U16 raw (percent), convert to 0..1 fraction
local bat_soc = 0
local ok_bsoc, bsoc_regs = pcall(host.modbus_read, 40321, 1, "holding")
if ok_bsoc and bsoc_regs then
bat_soc = apply_sf(bsoc_regs[1], soc_sf) / 100
end
-- Battery voltage: 40323, U16 raw × 10^bat_v_sf
local bat_v = 0
local ok_batv, batv_regs = pcall(host.modbus_read, 40323, 1, "holding")
if ok_batv and batv_regs then
bat_v = apply_sf(batv_regs[1], bat_v_sf)
end
-- Discharge rate % (I16): 40325
local discharge_rate = 0
local ok_dis, dis_regs = pcall(host.modbus_read, 40325, 1, "holding")
if ok_dis and dis_regs then
discharge_rate = apply_sf(host.decode_i16(dis_regs[1]), charge_rate_sf)
end
-- Charge rate % (I16): 40326
local charge_rate = 0
local ok_chg, chg_regs = pcall(host.modbus_read, 40326, 1, "holding")
if ok_chg and chg_regs then
charge_rate = apply_sf(host.decode_i16(chg_regs[1]), charge_rate_sf)
end
-- Site convention: positive W = charging, negative W = discharging.
-- Fronius reports direction as two separate percent rates + max power.
local bat_w = 0
if discharge_rate > 0 then
bat_w = -(discharge_rate / 100) * max_charge_w
elseif charge_rate > 0 then
bat_w = (charge_rate / 100) * max_charge_w
end
host.emit("battery", {
w = bat_w,
v = bat_v,
soc = bat_soc,
})
host.emit_metric("battery_dc_v", bat_v)
-- NOTE: This driver does NOT emit meter telemetry. A Fronius inverter is
-- NOT a grid meter — its AC output represents inverter production, not the
-- grid boundary. Operators need a separate meter driver (fronius_smart_meter.lua,
-- sdm630.lua, p1_meter.lua, etc.) with `is_site_meter: true` in config.yaml
-- for accurate grid power readings.
return 5000
end
----------------------------------------------------------------------------
-- Control (READ-ONLY driver — Fronius GEN24 battery control via SunSpec
-- requires the Modbus-control licence key and is not implemented here.)
----------------------------------------------------------------------------
function driver_command(action, power_w, cmd)
if action == "init" or action == "deinit" then
return true
end
host.log("warn", "Fronius: read-only driver, ignoring action=" .. tostring(action))
return false
end
function driver_default_mode()
-- Read-only: nothing to revert. Inverter runs its own self-consumption.
end
function driver_cleanup()
sn_read = false
end