Notifications
You must be signed in to change notification settings - Fork 6
Expand file tree
/
Copy pathgrowatt.lua
More file actions
259 lines (223 loc) · 8.35 KB
/
Copy pathgrowatt.lua
File metadata and controls
259 lines (223 loc) · 8.35 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
-- Growatt Hybrid Inverter Driver
-- Emits: PV, Battery, Meter (READ-ONLY)
-- Protocol: Modbus TCP, INPUT registers (FC 0x04), Big-Endian word order
--
-- Ported from sourceful-hugin/device-support/drivers/lua/growatt.lua
-- for FTW Lua host v2.1.
--
-- Sign convention (site convention — positive W = INTO the site):
-- pv.w: always negative (generation)
-- battery.w: positive = charging, negative = discharging
-- meter.w: positive = import from grid, negative = export
--
-- Growatt reports separate charge / discharge power registers; we
-- combine them into a signed site-convention value at the boundary.
-- The native meter register is already positive=import, so it maps
-- to site convention without a flip.
DRIVER = {
host_api_min = 1,
host_api_max = 1,
id = "growatt",
name = "Growatt hybrid inverter",
manufacturer = "Growatt",
version = "1.0.0",
protocols = { "modbus" },
capabilities = { "meter", "pv", "battery" },
description = "Growatt SPH / MOD hybrid inverters via Modbus TCP.",
homepage = "https://www.growatt.com",
authors = { "FTW contributors" },
tested_models = { "SPH", "MOD" },
verification_status = "experimental",
verification_notes = "Ported from a reference implementation. Not yet verified against live hardware on a FTW site.",
connection_defaults = {
port = 502,
unit_id = 1,
},
}
PROTOCOL = "modbus"
----------------------------------------------------------------------------
-- Initialization
----------------------------------------------------------------------------
function driver_init(config)
host.set_make("Growatt")
host.log("info", "Growatt: driver_init")
end
----------------------------------------------------------------------------
-- Telemetry polling
----------------------------------------------------------------------------
function driver_poll()
-- ---- PV ----
-- PV total power: 1-2, U32 BE × 0.1 W
local ok_pvw, pvw_regs = pcall(host.modbus_read, 1, 2, "input")
local pv_w = 0
if ok_pvw and pvw_regs then
pv_w = host.decode_u32_be(pvw_regs[1], pvw_regs[2]) * 0.1
end
-- PV1 V/A: 3-4, U16 × 0.1 V, U16 × 0.1 A
local ok_m1, m1_regs = pcall(host.modbus_read, 3, 2, "input")
local mppt1_v, mppt1_a = 0, 0
if ok_m1 and m1_regs then
mppt1_v = m1_regs[1] * 0.1
mppt1_a = m1_regs[2] * 0.1
end
-- PV2 V/A: 7-8, U16 × 0.1 V, U16 × 0.1 A
local ok_m2, m2_regs = pcall(host.modbus_read, 7, 2, "input")
local mppt2_v, mppt2_a = 0, 0
if ok_m2 and m2_regs then
mppt2_v = m2_regs[1] * 0.1
mppt2_a = m2_regs[2] * 0.1
end
-- Grid frequency: 37, U16 × 0.01 Hz
local ok_hz, hz_regs = pcall(host.modbus_read, 37, 1, "input")
local hz = 0
if ok_hz and hz_regs then
hz = hz_regs[1] * 0.01
end
-- Total PV lifetime energy: 91-92, U32 BE × 0.1 kWh → × 1000 for Wh
local ok_pvgen, pvgen_regs = pcall(host.modbus_read, 91, 2, "input")
local pv_gen_wh = 0
if ok_pvgen and pvgen_regs then
pv_gen_wh = host.decode_u32_be(pvgen_regs[1], pvgen_regs[2]) * 0.1 * 1000
end
-- Emit PV telemetry (site convention: generation is negative).
host.emit("pv", {
w = -pv_w,
mppt1_v = mppt1_v,
mppt1_a = mppt1_a,
mppt2_v = mppt2_v,
mppt2_a = mppt2_a,
lifetime_wh = pv_gen_wh,
})
host.emit_metric("pv_mppt1_v", mppt1_v)
host.emit_metric("pv_mppt1_a", mppt1_a)
host.emit_metric("pv_mppt2_v", mppt2_v)
host.emit_metric("pv_mppt2_a", mppt2_a)
host.emit_metric("grid_hz", hz)
-- ---- Battery ----
-- Battery charge power: 1009-1010, U32 BE × 0.1 W
local ok_bchgw, bchgw_regs = pcall(host.modbus_read, 1009, 2, "input")
local bat_charge_w = 0
if ok_bchgw and bchgw_regs then
bat_charge_w = host.decode_u32_be(bchgw_regs[1], bchgw_regs[2]) * 0.1
end
-- Battery discharge power: 1011-1012, U32 BE × 0.1 W
local ok_bdisw, bdisw_regs = pcall(host.modbus_read, 1011, 2, "input")
local bat_discharge_w = 0
if ok_bdisw and bdisw_regs then
bat_discharge_w = host.decode_u32_be(bdisw_regs[1], bdisw_regs[2]) * 0.1
end
-- Net battery power: positive = charging, negative = discharging (site convention).
local bat_w = bat_charge_w - bat_discharge_w
-- Battery voltage: 1013, U16 × 0.1 V
local ok_bv, bv_regs = pcall(host.modbus_read, 1013, 1, "input")
local bat_v = 0
if ok_bv and bv_regs then
bat_v = bv_regs[1] * 0.1
end
-- Battery SoC: 1014, U16, percent → 0-1 fraction
local ok_bsoc, bsoc_regs = pcall(host.modbus_read, 1014, 1, "input")
local bat_soc = 0
if ok_bsoc and bsoc_regs then
bat_soc = bsoc_regs[1] / 100
end
-- Battery temperature: 1040, U16 × 0.1 °C
local ok_btemp, btemp_regs = pcall(host.modbus_read, 1040, 1, "input")
local bat_temp = 0
if ok_btemp and btemp_regs then
bat_temp = btemp_regs[1] * 0.1
end
host.emit("battery", {
w = bat_w,
v = bat_v,
soc = bat_soc,
temp_c = bat_temp,
})
host.emit_metric("battery_dc_v", bat_v)
host.emit_metric("battery_temp_c", bat_temp)
-- ---- Meter ----
-- Meter total power: 1015-1016, I32 BE × 0.1 W
-- Growatt sign: positive = import (matches site convention).
local ok_mw, mw_regs = pcall(host.modbus_read, 1015, 2, "input")
local meter_w = 0
if ok_mw and mw_regs then
meter_w = host.decode_i32_be(mw_regs[1], mw_regs[2]) * 0.1
end
-- Per-phase voltages: L1=38, L2=42, L3=46, U16 × 0.1 V
local ok_lv1, lv1_regs = pcall(host.modbus_read, 38, 1, "input")
local l1_v = 0
if ok_lv1 and lv1_regs then
l1_v = lv1_regs[1] * 0.1
end
local ok_lv2, lv2_regs = pcall(host.modbus_read, 42, 1, "input")
local l2_v = 0
if ok_lv2 and lv2_regs then
l2_v = lv2_regs[1] * 0.1
end
local ok_lv3, lv3_regs = pcall(host.modbus_read, 46, 1, "input")
local l3_v = 0
if ok_lv3 and lv3_regs then
l3_v = lv3_regs[1] * 0.1
end
-- Per-phase currents: L1=39, L2=43, L3=47, U16 × 0.1 A
local ok_la1, la1_regs = pcall(host.modbus_read, 39, 1, "input")
local l1_a = 0
if ok_la1 and la1_regs then
l1_a = la1_regs[1] * 0.1
end
local ok_la2, la2_regs = pcall(host.modbus_read, 43, 1, "input")
local l2_a = 0
if ok_la2 and la2_regs then
l2_a = la2_regs[1] * 0.1
end
local ok_la3, la3_regs = pcall(host.modbus_read, 47, 1, "input")
local l3_a = 0
if ok_la3 and la3_regs then
l3_a = la3_regs[1] * 0.1
end
-- Total import energy: 1021-1022, U32 BE × 0.1 kWh → × 1000 for Wh
local ok_imp, imp_regs = pcall(host.modbus_read, 1021, 2, "input")
local import_wh = 0
if ok_imp and imp_regs then
import_wh = host.decode_u32_be(imp_regs[1], imp_regs[2]) * 0.1 * 1000
end
-- Total export energy: 1029-1030, U32 BE × 0.1 kWh → × 1000 for Wh
local ok_exp, exp_regs = pcall(host.modbus_read, 1029, 2, "input")
local export_wh = 0
if ok_exp and exp_regs then
export_wh = host.decode_u32_be(exp_regs[1], exp_regs[2]) * 0.1 * 1000
end
host.emit("meter", {
w = meter_w,
l1_v = l1_v,
l2_v = l2_v,
l3_v = l3_v,
l1_a = l1_a,
l2_a = l2_a,
l3_a = l3_a,
hz = hz,
import_wh = import_wh,
export_wh = export_wh,
})
host.emit_metric("meter_l1_v", l1_v)
host.emit_metric("meter_l2_v", l2_v)
host.emit_metric("meter_l3_v", l3_v)
host.emit_metric("meter_l1_a", l1_a)
host.emit_metric("meter_l2_a", l2_a)
host.emit_metric("meter_l3_a", l3_a)
return 5000
end
----------------------------------------------------------------------------
-- Control (read-only driver — no battery control implemented)
----------------------------------------------------------------------------
-- Read-only driver: control is not implemented. Returning false lets the
-- control loop register the no-op without flooding the log — the EMS
-- sends a battery dispatch every tick even when power_w = 0.
function driver_command(action, power_w, cmd)
return false
end
function driver_default_mode()
-- Read-only driver: device manages itself autonomously.
end
function driver_cleanup()
-- Nothing to clean up.
end