Notifications
You must be signed in to change notification settings - Fork 7
Expand file tree
/
Copy pathkostal.lua
More file actions
266 lines (231 loc) · 9.99 KB
/
Copy pathkostal.lua
File metadata and controls
266 lines (231 loc) · 9.99 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
-- Kostal Plenticore / Piko IQ hybrid inverter driver (SunSpec)
-- Emits: PV, Battery, Meter
-- Protocol: Modbus TCP, port 1502 (Kostal default), holding registers (FC 0x03)
-- Reference: Kostal SunSpec map. SunSpec is big-endian for u32 values.
-- READ-ONLY: no battery / curtail control.
DRIVER = {
host_api_min = 1,
host_api_max = 1,
id = "kostal",
name = "Kostal Plenticore",
manufacturer = "Kostal",
version = "1.0.0",
protocols = { "modbus" },
capabilities = { "meter", "pv", "battery" },
description = "Kostal Plenticore Plus and Piko IQ via Modbus TCP (SunSpec plus Kostal custom map).",
homepage = "https://www.kostal-solar-electric.com",
authors = { "FTW contributors" },
tested_models = { "Plenticore Plus", "Piko IQ" },
verification_status = "experimental",
verification_notes = "Ported from a reference implementation. Not yet verified against live hardware on a FTW site.",
connection_defaults = {
port = 502,
unit_id = 1,
},
}
PROTOCOL = "modbus"
----------------------------------------------------------------------------
-- SunSpec helpers (inline — the FTW host has no host.scale / host.decode_f32)
----------------------------------------------------------------------------
-- Apply a SunSpec signed scale factor: result = value * 10^sf.
-- sf is a small int16 (typical range -4..+4). Negative sf divides.
local function apply_sf(v, sf)
if sf >= 0 then return v * (10 ^ sf) end
return v / (10 ^ -sf)
end
-- Read a single holding register as signed i16 (e.g. scale factors).
-- Returns the decoded value, or the default if the read fails.
local function read_i16(addr, default)
local ok, regs = pcall(host.modbus_read, addr, 1, "holding")
if ok and regs and regs[1] then
return host.decode_i16(regs[1])
end
return default
end
-- Read a single holding register as unsigned u16.
local function read_u16(addr, default)
local ok, regs = pcall(host.modbus_read, addr, 1, "holding")
if ok and regs and regs[1] then
return regs[1]
end
return default
end
-- Read a u32 big-endian pair (SunSpec standard word order).
local function read_u32_be(addr, default)
local ok, regs = pcall(host.modbus_read, addr, 2, "holding")
if ok and regs and regs[1] and regs[2] then
return host.decode_u32_be(regs[1], regs[2])
end
return default
end
----------------------------------------------------------------------------
-- Lifecycle
----------------------------------------------------------------------------
local sn_read = false
function driver_init(config)
host.set_make("Kostal")
host.log("info", "Kostal: initialised, SunSpec Modbus TCP (holding registers)")
end
function driver_poll()
-- -----------------------------------------------------------------
-- Serial number (SunSpec Common Model 1: SN at regs 40052-40067,
-- 16 regs = 32 chars ASCII. NOTE: 40004-40019 is Md (manufacturer),
-- 40020-40035 is Opt (model string) — NOT serial number.)
-- -----------------------------------------------------------------
if not sn_read then
local ok_sn, sn_regs = pcall(host.modbus_read, 40052, 16, "holding")
if ok_sn and sn_regs then
local sn = ""
for i = 1, 16 do
local hi = math.floor(sn_regs[i] / 256)
local lo = sn_regs[i] % 256
if hi > 32 and hi < 127 then sn = sn .. string.char(hi) end
if lo > 32 and lo < 127 then sn = sn .. string.char(lo) end
end
if string.len(sn) > 0 then
host.set_sn(sn)
sn_read = true
end
end
end
-- -----------------------------------------------------------------
-- Scale factors (SunSpec inverter model 103)
-- -----------------------------------------------------------------
local ac_power_sf = read_i16(40084, 0) -- AC power SF
local hz_sf = read_i16(40086, 0) -- Hz SF
local energy_sf = read_i16(40095, 0) -- Lifetime energy SF
local temp_sf = read_i16(40106, 0) -- Heatsink temp SF
-- MPPT scale factors (SunSpec model 160, base 40253)
local mppt_a_sf = read_i16(40255, 0) -- DCA_SF (+2 from base)
local mppt_v_sf = read_i16(40256, 0) -- DCV_SF (+3 from base)
-- -----------------------------------------------------------------
-- PV (SunSpec inverter model 103)
-- -----------------------------------------------------------------
local ac_w_raw = read_i16(40083, 0)
local ac_w = apply_sf(ac_w_raw, ac_power_sf)
local hz_raw = read_u16(40085, 0)
local hz = apply_sf(hz_raw, hz_sf)
local lifetime_raw = read_u32_be(40093, 0)
local lifetime_wh = apply_sf(lifetime_raw, energy_sf)
local temp_raw = read_i16(40103, 0)
local temp_c = apply_sf(temp_raw, temp_sf)
-- MPPT1: module 1 current @ 40260, voltage @ 40261
local mppt1_a = apply_sf(read_u16(40260, 0), mppt_a_sf)
local mppt1_v = apply_sf(read_u16(40261, 0), mppt_v_sf)
-- MPPT2: module 2 current @ 40280, voltage @ 40281
local mppt2_a = apply_sf(read_u16(40280, 0), mppt_a_sf)
local mppt2_v = apply_sf(read_u16(40281, 0), mppt_v_sf)
-- PV emit: w is always negative (generation leaves the array)
host.emit("pv", {
w = -ac_w,
mppt1_v = mppt1_v,
mppt1_a = mppt1_a,
mppt2_v = mppt2_v,
mppt2_a = mppt2_a,
lifetime_wh = lifetime_wh,
temp_c = temp_c,
})
host.emit_metric("pv_mppt1_v", mppt1_v)
host.emit_metric("pv_mppt1_a", mppt1_a)
host.emit_metric("pv_mppt2_v", mppt2_v)
host.emit_metric("pv_mppt2_a", mppt2_a)
host.emit_metric("inverter_temp_c", temp_c)
host.emit_metric("grid_hz", hz)
-- -----------------------------------------------------------------
-- Battery (SunSpec storage model 124 — Kostal custom offsets)
-- -----------------------------------------------------------------
-- SoC @ 40137, %; battery power @ 40138, i16 W (+ = charge, - = discharge)
local bat_soc_raw = read_u16(40137, 0)
local bat_soc = bat_soc_raw / 100.0 -- percent → 0-1 fraction
local bat_w = 0
local ok_bw, bw_regs = pcall(host.modbus_read, 40138, 1, "holding")
if ok_bw and bw_regs and bw_regs[1] then
-- Kostal reports battery power with EMS-compatible sign already:
-- positive = charging, negative = discharging.
bat_w = host.decode_i16(bw_regs[1])
end
host.emit("battery", {
w = bat_w,
soc = bat_soc,
})
-- -----------------------------------------------------------------
-- Meter (SunSpec meter model 203 — Kostal custom offsets)
-- -----------------------------------------------------------------
local meter_w_sf = read_i16(40210, 0) -- total W SF (also phase W SF)
local meter_a_sf = read_i16(40194, 0) -- per-phase A SF
local meter_v_sf = read_i16(40203, 0) -- per-phase V SF
local meter_energy_sf = read_i16(40242, 0) -- meter energy SF
-- Total grid power: 40100, I16 (Kostal reports meter W at inverter 40100)
local meter_w_raw = read_i16(40100, 0)
-- SunSpec convention at this map negates vs site convention (+ = export).
-- Flip to site convention: + = import, - = export.
local meter_w = -apply_sf(meter_w_raw, meter_w_sf)
-- Per-phase current: 40191-40193, I16
local l1_a, l2_a, l3_a = 0, 0, 0
local ok_la, la_regs = pcall(host.modbus_read, 40191, 3, "holding")
if ok_la and la_regs then
l1_a = -apply_sf(host.decode_i16(la_regs[1]), meter_a_sf)
l2_a = -apply_sf(host.decode_i16(la_regs[2]), meter_a_sf)
l3_a = -apply_sf(host.decode_i16(la_regs[3]), meter_a_sf)
end
-- Per-phase voltage: 40196-40198, I16
local l1_v, l2_v, l3_v = 0, 0, 0
local ok_lv, lv_regs = pcall(host.modbus_read, 40196, 3, "holding")
if ok_lv and lv_regs then
l1_v = apply_sf(host.decode_i16(lv_regs[1]), meter_v_sf)
l2_v = apply_sf(host.decode_i16(lv_regs[2]), meter_v_sf)
l3_v = apply_sf(host.decode_i16(lv_regs[3]), meter_v_sf)
end
-- Per-phase power: 40207-40209, I16
local l1_w, l2_w, l3_w = 0, 0, 0
local ok_lw, lw_regs = pcall(host.modbus_read, 40207, 3, "holding")
if ok_lw and lw_regs then
l1_w = -apply_sf(host.decode_i16(lw_regs[1]), meter_w_sf)
l2_w = -apply_sf(host.decode_i16(lw_regs[2]), meter_w_sf)
l3_w = -apply_sf(host.decode_i16(lw_regs[3]), meter_w_sf)
end
-- Energy counters: 40226-40227 export, 40234-40235 import, U32 BE
local export_wh = apply_sf(read_u32_be(40226, 0), meter_energy_sf)
local import_wh = apply_sf(read_u32_be(40234, 0), meter_energy_sf)
host.emit("meter", {
w = meter_w,
l1_w = l1_w,
l2_w = l2_w,
l3_w = l3_w,
l1_v = l1_v,
l2_v = l2_v,
l3_v = l3_v,
l1_a = l1_a,
l2_a = l2_a,
l3_a = l3_a,
hz = hz,
import_wh = import_wh,
export_wh = export_wh,
})
host.emit_metric("meter_l1_w", l1_w)
host.emit_metric("meter_l2_w", l2_w)
host.emit_metric("meter_l3_w", l3_w)
host.emit_metric("meter_l1_v", l1_v)
host.emit_metric("meter_l2_v", l2_v)
host.emit_metric("meter_l3_v", l3_v)
host.emit_metric("meter_l1_a", l1_a)
host.emit_metric("meter_l2_a", l2_a)
host.emit_metric("meter_l3_a", l3_a)
return 5000
end
----------------------------------------------------------------------------
-- Control (READ-ONLY for this driver — Kostal write map is tier-locked)
----------------------------------------------------------------------------
function driver_command(action, power_w, cmd)
-- Read-only driver: accept "init" (EMS handshake) and ignore the rest.
if action == "init" then
return true
end
return false
end
function driver_default_mode()
-- Read-only driver — device stays in its own autonomous mode.
end
function driver_cleanup()
-- Nothing to clean up.
end