Notifications
You must be signed in to change notification settings - Fork 6
Expand file tree
/
Copy pathsma.lua
More file actions
363 lines (320 loc) · 13.1 KB
/
Copy pathsma.lua
File metadata and controls
363 lines (320 loc) · 13.1 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
-- SMA Hybrid Inverter Driver
-- Emits: PV, Battery, Meter
-- Protocol: Modbus TCP (all registers are INPUT, SunSpec, Big-Endian)
-- Tested: SMA Sunny Tripower, Sunny Boy Storage
--
-- Ported from sourceful-hugin/device-support/drivers/lua/sma.lua to the
-- FTW v2.1 Lua host idiom. READ-ONLY driver — SMA control is
-- not wired up here.
DRIVER = {
host_api_min = 1,
host_api_max = 1,
id = "sma",
name = "SMA hybrid inverter",
manufacturer = "SMA",
version = "1.0.0",
protocols = { "modbus" },
capabilities = { "meter", "pv", "battery" },
description = "SMA Sunny Tripower / Sunny Boy Storage via Modbus TCP (SunSpec).",
homepage = "https://www.sma.de",
authors = { "FTW contributors" },
tested_models = { "Sunny Tripower", "Sunny Boy Storage" },
verification_status = "experimental",
verification_notes = "Ported from a reference implementation. Not yet verified against live hardware on a FTW site.",
connection_defaults = {
port = 502,
unit_id = 1,
},
}
PROTOCOL = "modbus"
----------------------------------------------------------------------------
-- Local helpers
----------------------------------------------------------------------------
-- Combine four big-endian uint16 registers into a non-negative 64-bit
-- counter. Lua 5.1 numbers are IEEE-754 doubles, so values up to 2^53
-- are exact — energy counters in Wh fit comfortably.
local function decode_u64_be(h1, h2, h3, h4)
h1 = h1 % 65536
h2 = h2 % 65536
h3 = h3 % 65536
h4 = h4 % 65536
return ((h1 * 65536 + h2) * 65536 + h3) * 65536 + h4
end
-- SunSpec "not implemented" sentinel values. SMA registers that are not
-- populated return these magic numbers; clamping them to 0 keeps
-- telemetry sane.
local function u32_valid(v)
-- 0xFFFFFFFF = U32 NaN
return v ~= 4294967295
end
local function i32_valid(v)
-- 0x80000000 (as signed -2147483648) = I32 NaN
return v ~= -2147483648
end
-- 0xFFFFFFFFFFFFFFFF = U64 NaN. All four words 0xFFFF means sentinel.
local function u64_valid(h1, h2, h3, h4)
return not (h1 == 65535 and h2 == 65535 and h3 == 65535 and h4 == 65535)
end
local sn_read = false
----------------------------------------------------------------------------
-- Lifecycle
----------------------------------------------------------------------------
function driver_init(config)
host.set_make("SMA")
-- SunSpec common model serial number: 30057-30058 (U32 BE).
-- Best-effort; older SMA firmware can report 0 here — we fall back
-- to make:endpoint identity in that case.
local ok, sn_regs = pcall(host.modbus_read, 30057, 2, "input")
if ok and sn_regs then
local sn = host.decode_u32_be(sn_regs[1], sn_regs[2])
if u32_valid(sn) and sn > 0 then
host.set_sn(tostring(sn))
sn_read = true
end
end
end
function driver_poll()
-- Opportunistically retry SN if init couldn't read it (e.g. the
-- inverter was still booting).
if not sn_read then
local ok, sn_regs = pcall(host.modbus_read, 30057, 2, "input")
if ok and sn_regs then
local sn = host.decode_u32_be(sn_regs[1], sn_regs[2])
if u32_valid(sn) and sn > 0 then
host.set_sn(tostring(sn))
sn_read = true
end
end
end
------------------------------------------------------------------ PV --
-- PV power: 30775-30776, I32 BE, watts
local ok_pvw, pvw_regs = pcall(host.modbus_read, 30775, 2, "input")
local pv_w = 0
if ok_pvw and pvw_regs then
local v = host.decode_i32_be(pvw_regs[1], pvw_regs[2])
if i32_valid(v) then pv_w = v end
end
-- MPPT1 current: 30769-30770, I32 BE × 0.001 A
local ok_m1a, m1a_regs = pcall(host.modbus_read, 30769, 2, "input")
local mppt1_a = 0
if ok_m1a and m1a_regs then
local v = host.decode_i32_be(m1a_regs[1], m1a_regs[2])
if i32_valid(v) then mppt1_a = v * 0.001 end
end
-- MPPT1 voltage: 30771-30772, I32 BE × 0.01 V
local ok_m1v, m1v_regs = pcall(host.modbus_read, 30771, 2, "input")
local mppt1_v = 0
if ok_m1v and m1v_regs then
local v = host.decode_i32_be(m1v_regs[1], m1v_regs[2])
if i32_valid(v) then mppt1_v = v * 0.01 end
end
-- MPPT2 current: 30957-30958, I32 BE × 0.001 A
local ok_m2a, m2a_regs = pcall(host.modbus_read, 30957, 2, "input")
local mppt2_a = 0
if ok_m2a and m2a_regs then
local v = host.decode_i32_be(m2a_regs[1], m2a_regs[2])
if i32_valid(v) then mppt2_a = v * 0.001 end
end
-- MPPT2 voltage: 30959-30960, I32 BE × 0.01 V
local ok_m2v, m2v_regs = pcall(host.modbus_read, 30959, 2, "input")
local mppt2_v = 0
if ok_m2v and m2v_regs then
local v = host.decode_i32_be(m2v_regs[1], m2v_regs[2])
if i32_valid(v) then mppt2_v = v * 0.01 end
end
-- PV lifetime generation: 30513-30516, U64 BE, Wh
local ok_pvgen, pvgen_regs = pcall(host.modbus_read, 30513, 4, "input")
local pv_gen_wh = 0
if ok_pvgen and pvgen_regs and u64_valid(pvgen_regs[1], pvgen_regs[2], pvgen_regs[3], pvgen_regs[4]) then
pv_gen_wh = decode_u64_be(pvgen_regs[1], pvgen_regs[2], pvgen_regs[3], pvgen_regs[4])
end
-- Inverter heatsink temp: 30953-30954, I32 BE × 0.1 C
local ok_itemp, itemp_regs = pcall(host.modbus_read, 30953, 2, "input")
local inv_temp = 0
if ok_itemp and itemp_regs then
local v = host.decode_i32_be(itemp_regs[1], itemp_regs[2])
if i32_valid(v) then inv_temp = v * 0.1 end
end
-- Rated power: 31085-31086, U32 BE, watts
local ok_rated, rated_regs = pcall(host.modbus_read, 31085, 2, "input")
local rated_w = 0
if ok_rated and rated_regs then
local v = host.decode_u32_be(rated_regs[1], rated_regs[2])
if u32_valid(v) then rated_w = v end
end
host.emit("pv", {
w = -pv_w, -- site convention: generation is negative
mppt1_v = mppt1_v,
mppt1_a = mppt1_a,
mppt2_v = mppt2_v,
mppt2_a = mppt2_a,
lifetime_wh = pv_gen_wh,
temp_c = inv_temp,
rated_w = rated_w,
})
host.emit_metric("pv_mppt1_v", mppt1_v)
host.emit_metric("pv_mppt1_a", mppt1_a)
host.emit_metric("pv_mppt2_v", mppt2_v)
host.emit_metric("pv_mppt2_a", mppt2_a)
host.emit_metric("inverter_temp_c", inv_temp)
------------------------------------------------------------- Battery --
-- Battery current: 30843-30844, I32 BE × 0.001 A (+ = charging)
local ok_ba, ba_regs = pcall(host.modbus_read, 30843, 2, "input")
local bat_a = 0
if ok_ba and ba_regs then
local v = host.decode_i32_be(ba_regs[1], ba_regs[2])
if i32_valid(v) then bat_a = v * 0.001 end
end
-- Battery SoC: 30845-30846, U32 BE, percent → fraction
local ok_bsoc, bsoc_regs = pcall(host.modbus_read, 30845, 2, "input")
local bat_soc = 0
if ok_bsoc and bsoc_regs then
local v = host.decode_u32_be(bsoc_regs[1], bsoc_regs[2])
if u32_valid(v) then bat_soc = v / 100 end
end
-- Battery temperature: 30849-30850, I32 BE × 0.1 C
local ok_btemp, btemp_regs = pcall(host.modbus_read, 30849, 2, "input")
local bat_temp = 0
if ok_btemp and btemp_regs then
local v = host.decode_i32_be(btemp_regs[1], btemp_regs[2])
if i32_valid(v) then bat_temp = v * 0.1 end
end
-- Battery voltage: 30851-30852, U32 BE × 0.01 V
local ok_bv, bv_regs = pcall(host.modbus_read, 30851, 2, "input")
local bat_v = 0
if ok_bv and bv_regs then
local v = host.decode_u32_be(bv_regs[1], bv_regs[2])
if u32_valid(v) then bat_v = v * 0.01 end
end
-- Battery power: V*A. Site convention matches native here because
-- SMA reports signed current (+ = charging = into battery).
local bat_w = bat_v * bat_a
-- Battery charge energy: 31397-31400, U64 BE, Wh
local ok_bchg, bchg_regs = pcall(host.modbus_read, 31397, 4, "input")
local bat_charge_wh = 0
if ok_bchg and bchg_regs and u64_valid(bchg_regs[1], bchg_regs[2], bchg_regs[3], bchg_regs[4]) then
bat_charge_wh = decode_u64_be(bchg_regs[1], bchg_regs[2], bchg_regs[3], bchg_regs[4])
end
-- Battery discharge energy: 31401-31404, U64 BE, Wh
local ok_bdis, bdis_regs = pcall(host.modbus_read, 31401, 4, "input")
local bat_discharge_wh = 0
if ok_bdis and bdis_regs and u64_valid(bdis_regs[1], bdis_regs[2], bdis_regs[3], bdis_regs[4]) then
bat_discharge_wh = decode_u64_be(bdis_regs[1], bdis_regs[2], bdis_regs[3], bdis_regs[4])
end
host.emit("battery", {
w = bat_w,
v = bat_v,
a = bat_a,
soc = bat_soc,
temp_c = bat_temp,
charge_wh = bat_charge_wh,
discharge_wh = bat_discharge_wh,
})
host.emit_metric("battery_dc_v", bat_v)
host.emit_metric("battery_dc_a", bat_a)
host.emit_metric("battery_temp_c", bat_temp)
--------------------------------------------------------------- Meter --
-- Meter total power: 30885-30886, I32 BE, watts (signed: + = import, - = export)
local ok_mw, mw_regs = pcall(host.modbus_read, 30885, 2, "input")
local meter_w = 0
if ok_mw and mw_regs then
local v = host.decode_i32_be(mw_regs[1], mw_regs[2])
if i32_valid(v) then meter_w = v end
end
-- Per-phase meter power: 30887-30892, I32 BE pairs, watts (signed)
local ok_mpw, mpw_regs = pcall(host.modbus_read, 30887, 6, "input")
local l1_w, l2_w, l3_w = 0, 0, 0
if ok_mpw and mpw_regs then
local v1 = host.decode_i32_be(mpw_regs[1], mpw_regs[2])
local v2 = host.decode_i32_be(mpw_regs[3], mpw_regs[4])
local v3 = host.decode_i32_be(mpw_regs[5], mpw_regs[6])
if i32_valid(v1) then l1_w = v1 end
if i32_valid(v2) then l2_w = v2 end
if i32_valid(v3) then l3_w = v3 end
end
-- Grid frequency: 30901-30902, U32 BE × 0.01 Hz
local ok_hz, hz_regs = pcall(host.modbus_read, 30901, 2, "input")
local hz = 0
if ok_hz and hz_regs then
local v = host.decode_u32_be(hz_regs[1], hz_regs[2])
if u32_valid(v) then hz = v * 0.01 end
end
-- Per-phase voltage: 30903-30908, U32 BE × 0.01 V pairs
local ok_lv, lv_regs = pcall(host.modbus_read, 30903, 6, "input")
local l1_v, l2_v, l3_v = 0, 0, 0
if ok_lv and lv_regs then
local v1 = host.decode_u32_be(lv_regs[1], lv_regs[2])
local v2 = host.decode_u32_be(lv_regs[3], lv_regs[4])
local v3 = host.decode_u32_be(lv_regs[5], lv_regs[6])
if u32_valid(v1) then l1_v = v1 * 0.01 end
if u32_valid(v2) then l2_v = v2 * 0.01 end
if u32_valid(v3) then l3_v = v3 * 0.01 end
end
-- Per-phase current: 30909-30914, U32 BE × 0.001 A pairs
local ok_la, la_regs = pcall(host.modbus_read, 30909, 6, "input")
local l1_a, l2_a, l3_a = 0, 0, 0
if ok_la and la_regs then
local v1 = host.decode_u32_be(la_regs[1], la_regs[2])
local v2 = host.decode_u32_be(la_regs[3], la_regs[4])
local v3 = host.decode_u32_be(la_regs[5], la_regs[6])
if u32_valid(v1) then l1_a = v1 * 0.001 end
if u32_valid(v2) then l2_a = v2 * 0.001 end
if u32_valid(v3) then l3_a = v3 * 0.001 end
end
-- Import energy: 30581-30582, U32 BE, Wh
local ok_imp, imp_regs = pcall(host.modbus_read, 30581, 2, "input")
local import_wh = 0
if ok_imp and imp_regs then
local v = host.decode_u32_be(imp_regs[1], imp_regs[2])
if u32_valid(v) then import_wh = v end
end
-- Export energy: 30583-30584, U32 BE, Wh
local ok_exp, exp_regs = pcall(host.modbus_read, 30583, 2, "input")
local export_wh = 0
if ok_exp and exp_regs then
local v = host.decode_u32_be(exp_regs[1], exp_regs[2])
if u32_valid(v) then export_wh = v end
end
host.emit("meter", {
w = meter_w,
l1_w = l1_w,
l2_w = l2_w,
l3_w = l3_w,
l1_v = l1_v,
l2_v = l2_v,
l3_v = l3_v,
l1_a = l1_a,
l2_a = l2_a,
l3_a = l3_a,
hz = hz,
import_wh = import_wh,
export_wh = export_wh,
})
host.emit_metric("meter_l1_w", l1_w)
host.emit_metric("meter_l2_w", l2_w)
host.emit_metric("meter_l3_w", l3_w)
host.emit_metric("meter_l1_v", l1_v)
host.emit_metric("meter_l2_v", l2_v)
host.emit_metric("meter_l3_v", l3_v)
host.emit_metric("meter_l1_a", l1_a)
host.emit_metric("meter_l2_a", l2_a)
host.emit_metric("meter_l3_a", l3_a)
host.emit_metric("grid_hz", hz)
return 5000
end
----------------------------------------------------------------------------
-- Control (read-only — SMA control is not implemented)
----------------------------------------------------------------------------
function driver_command(action, power_w, cmd)
if action == "init" then
return true
end
host.log("warn", "SMA: control not implemented (action=" .. tostring(action) .. ")")
return false
end
function driver_default_mode()
-- Read-only driver: nothing to revert.
end
function driver_cleanup()
-- Read-only driver: nothing to clean up.
end