Notifications
You must be signed in to change notification settings - Fork 6
Expand file tree
/
Copy pathsolaredge.lua
More file actions
520 lines (477 loc) · 19.8 KB
/
Copy pathsolaredge.lua
File metadata and controls
520 lines (477 loc) · 19.8 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
-- solaredge.lua
-- SolarEdge inverter + meter driver (SunSpec over Modbus TCP).
-- Emits: PV, Meter. READ-ONLY. Tested on HD-Wave and StorEdge.
--
-- Ported from sourceful-hugin/device-support/drivers/lua/solaredge.lua.
-- Differences vs hugin source:
-- * Uses FTW v2.1 host idiom (host.log(level,msg), decode_u32_be,
-- host.emit_metric).
-- * SunSpec scale factor + pow10 applied inline in Lua (host.scale is
-- not available in v2.1).
-- * Adds SunSpec common-block SN read (register 40052, 16 regs ASCII)
-- so device identity resolves to make:serial.
-- * Diagnostics (MPPT, heatsink, grid Hz, per-phase) routed through
-- host.emit_metric into the long-format TS DB.
DRIVER = {
host_api_min = 1,
host_api_max = 1,
id = "solaredge",
name = "SolarEdge inverter + meter",
manufacturer = "SolarEdge",
version = "1.1.0",
protocols = { "modbus" },
capabilities = { "meter", "pv", "pv-curtail" },
description = "SolarEdge HD-Wave / StorEdge via Modbus TCP (SunSpec) with PV active-power-limit curtail.",
homepage = "https://www.solaredge.com",
authors = { "FTW contributors" },
tested_models = { "HD-Wave", "StorEdge" },
verification_status = "experimental",
verification_notes = "Ported from a reference implementation. Curtail path (F000/F001 registers) not yet verified against live hardware on a FTW site.",
connection_defaults = {
port = 502,
unit_id = 1,
},
}
--
-- PV curtail (action="curtail" / "curtail_disable")
--
-- Uses SolarEdge's proprietary "Advanced Power Control" registers
-- (Application Note: Power Reduction Interface):
-- 0xF000 (61440) Advanced Power Control enable: 0 = off, 1 = on
-- 0xF001 (61441) Active Power Limit: u16, percent 0..100
-- Writes go to FC 0x06 (single-register holding write) via
-- host.modbus_write. SetApp setting "Limit Control Mode = Export
-- Control / Production" must be enabled on the inverter — without it,
-- writes succeed but the inverter ignores the limit.
--
-- power_w → percent conversion uses `nominal_w` from the YAML driver
-- config block (the inverter's rated active power output in W). If
-- nominal_w isn't set, curtail logs a warning and returns false so the
-- operator notices the missing config rather than silently producing
-- bogus limits.
--
-- Failsafe: F000/F001 do NOT auto-revert on SolarEdge. The driver
-- writes F000=0 on `curtail_disable`, `deinit`, and `driver_cleanup`.
-- If the daemon dies unexpectedly while curtailed, the inverter stays
-- capped until SetApp manually clears it.
--
-- SunSpec register map (FC 0x04 / "input" on SolarEdge; they intentionally
-- mirror the SunSpec common + inverter + meter blocks there):
--
-- Common block (device identity):
-- 40052-40067 SN (16 regs, ASCII, null-padded)
--
-- Inverter model (101/102/103):
-- 40083 AC power (I16) * 10^ac_power_sf
-- 40084 AC power SF (I16)
-- 40085 Frequency (U16) * 10^hz_sf
-- 40086 Frequency SF (I16)
-- 40093-40094 Lifetime Wh (U32 BE) * 10^energy_sf
-- 40095 Energy SF (I16 via i16 decode; datasheet calls it U16)
-- 40103 Heat-sink °C (I16) * 10^temp_sf
-- 40106 Temp SF (I16)
-- 40123 MPPT current SF (I16)
-- 40124 MPPT voltage SF (I16)
-- 40140-40141 MPPT1 A/V (U16 each)
-- 40160-40161 MPPT2 A/V (U16 each)
--
-- Meter model (203 — 3-phase wye):
-- 40100 Total W (I16) * 10^meter_w_sf
-- 40101 Meter W SF (I16)
-- 40191-40193 Per-phase A (I16) * 10^meter_a_sf
-- 40194 Meter A SF (I16)
-- 40196-40198 Per-phase V (I16) * 10^meter_v_sf
-- 40203 Meter V SF (I16)
-- 40207-40209 Per-phase W (I16) * 10^phase_w_sf
-- 40210 Phase W SF (I16)
-- 40226-40227 Export Wh (U32 BE) * 10^meter_energy_sf
-- 40234-40235 Import Wh (U32 BE) * 10^meter_energy_sf
-- 40242 Meter energy SF (I16)
--
-- Sign translation to site convention (positive = into site):
-- AC power out of the inverter = generation → PV w = -ac_w.
-- SolarEdge meter reports with utility-meter convention inverted
-- (+ = export in their datasheet), so we negate W and A to match
-- site convention (+ = import).
PROTOCOL = "modbus"
-- Cached per-device metadata. Scale factors are factory-set constants
-- (SunSpec guarantees they never change during a session), so we read
-- them once and cache. That cuts 11 Modbus round trips per poll.
-- However, if the first read attempt fails (returns zeros), we retry on
-- subsequent polls until all SFs are non-zero or we exhaust retries.
local sn_read = false
local sf_cache = nil
local sf_retries = 0
local SF_MAX_RETRIES = 5
-- Curtail state. nominal_w comes from the YAML driver config block.
-- curtail_active tracks whether F000 is currently set to 1, so we
-- don't redundantly re-enable on every refresh tick.
local nominal_w = 0
local curtail_active = false
-- SolarEdge "Advanced Power Control" register addresses (proprietary).
local REG_APC_ENABLE = 61440 -- 0xF000 u16 0 = disabled, 1 = enabled
local REG_APC_LIMIT = 61441 -- 0xF001 u16 percent 0..100
----------------------------------------------------------------------------
-- SunSpec helpers
----------------------------------------------------------------------------
-- Raw integer power of ten — avoids math.pow (Lua 5.1 still has it, but
-- 5.3+ removed it and we prefer portable code). Scale factors are small
-- integers, typically -3..+3, so a fixed table is fastest and clearest.
local POW10 = {
[-6] = 1e-6, [-5] = 1e-5, [-4] = 1e-4, [-3] = 1e-3,
[-2] = 1e-2, [-1] = 1e-1, [0] = 1,
[1] = 10, [2] = 100, [3] = 1000, [4] = 10000, [5] = 100000, [6] = 1e6,
}
-- SunSpec scale factors use 0x8000 (= -32768 after i16 decode) as a
-- "not implemented" sentinel. Treat that, and any out-of-range sf, as 0
-- (i.e. don't scale) — better to report a raw register than NaN out.
local function pow10(sf)
if sf == -32768 then return 1 end
local p = POW10[sf]
if p ~= nil then return p end
return 1
end
-- Apply a SunSpec scale factor inline: value * 10^sf.
-- value may be any lua number (already decoded i16/u16/u32/i32).
local function scale(value, sf)
return value * pow10(sf)
end
-- Read a single register and return it as an i16 (signed) scale factor.
-- Returns 0 on read failure so downstream scaling becomes a no-op (the
-- caller will get raw register values until the next retry).
local function read_sf(addr)
local ok, regs = pcall(host.modbus_read, addr, 1, "input")
if ok and regs then
return host.decode_i16(regs[1])
end
return 0
end
-- Populate sf_cache with every SunSpec scale factor we need. Returns the
-- table whether or not every read succeeded — a failed read just leaves
-- that SF at 0 until we retry (see load_scale_factors call site).
local function load_scale_factors()
return {
ac_power = read_sf(40084),
hz = read_sf(40086),
energy = read_sf(40095),
temp = read_sf(40106),
mppt_a = read_sf(40123),
mppt_v = read_sf(40124),
meter_w = read_sf(40101),
meter_a = read_sf(40194),
meter_v = read_sf(40203),
phase_w = read_sf(40210),
meter_energy = read_sf(40242),
}
end
-- Decode a null-/space-padded ASCII string from a run of registers
-- (SunSpec common-block strings — high byte first inside each reg).
local function decode_ascii(regs, n)
local s = ""
for i = 1, n do
local r = regs[i] or 0
local hi = math.floor(r / 256)
local lo = r % 256
if hi > 32 and hi < 127 then s = s .. string.char(hi) end
if lo > 32 and lo < 127 then s = s .. string.char(lo) end
end
return s
end
----------------------------------------------------------------------------
-- Fingerprint
----------------------------------------------------------------------------
-- driver_fingerprint() — passive probe used by /api/drivers/fingerprint to
-- auto-detect what's listening on a Modbus endpoint. NEVER writes to the
-- device (no curtail-register access here). Tri-state:
-- true → SunSpec common block reports manufacturer "SolarEdge"
-- false → responded, but it's a non-SolarEdge device (no SunSpec marker,
-- or a SunSpec marker from another vendor)
-- nil → couldn't read (wrong unit id, not Modbus, timeout) → inconclusive
function driver_fingerprint()
-- SunSpec identifier "SunS" lives at 40000-40001 (0x5375, 0x6E53).
local ok, sid = pcall(host.modbus_read, 40000, 2, "input")
if not ok or sid == nil or sid[1] == nil or sid[2] == nil then
return nil
end
if sid[1] ~= 0x5375 or sid[2] ~= 0x6E53 then
return false -- answered Modbus but not a SunSpec device
end
-- Common block manufacturer string at 40004 (16 regs ASCII).
local mok, mfg_regs = pcall(host.modbus_read, 40004, 16, "input")
if not mok or mfg_regs == nil then
return nil
end
local mfg = decode_ascii(mfg_regs, 16)
if mfg:sub(1, 9) ~= "SolarEdge" then
return false -- SunSpec, but a different vendor (Fronius, SMA, …)
end
local serial = ""
local sok, sn_regs = pcall(host.modbus_read, 40052, 16, "input")
if sok and sn_regs ~= nil then
serial = decode_ascii(sn_regs, 16)
end
return true, { make = "SolarEdge", serial = serial, confidence = 0.97 }
end
----------------------------------------------------------------------------
-- Lifecycle
----------------------------------------------------------------------------
function driver_init(config)
host.set_make("SolarEdge")
if type(config) == "table" then
local n = tonumber(config.nominal_w)
if n and n > 0 then
nominal_w = n
host.log("info", "SolarEdge: nominal_w = " .. tostring(nominal_w) .. " W (curtail enabled)")
end
end
if nominal_w <= 0 then
host.log("info", "SolarEdge: nominal_w not set in config — curtail action will be unavailable")
end
end
function driver_poll()
-- ---- Serial number (SunSpec common block, one-shot) ----
if not sn_read then
local ok_sn, sn_regs = pcall(host.modbus_read, 40052, 16, "input")
if ok_sn and sn_regs then
local sn = decode_ascii(sn_regs, 16)
if #sn > 0 then
host.set_sn(sn)
sn_read = true
end
end
end
-- ---- Scale factors (cached with retry on zero reads) ----
-- A failed modbus read returns 0 from read_sf(), which would cause raw
-- register values to be emitted unscaled — wrong by orders of magnitude.
-- Re-read all SFs until none are 0 or we exhaust retries.
local need_sf_read = (sf_cache == nil)
if not need_sf_read and sf_retries < SF_MAX_RETRIES then
for _, v in pairs(sf_cache) do
if v == 0 then need_sf_read = true; break end
end
end
if need_sf_read then
local fresh = load_scale_factors()
if sf_cache == nil then
-- First read: accept everything (zeros will trigger retries).
sf_cache = fresh
else
-- Merge: only overwrite with non-zero values so a transient
-- read failure doesn't clobber a previously good SF.
for k, v in pairs(fresh) do
if v ~= 0 then sf_cache[k] = v end
end
end
sf_retries = sf_retries + 1
if sf_retries >= SF_MAX_RETRIES then
host.log("warn", "SolarEdge: accepting scale factors after "
.. tostring(SF_MAX_RETRIES) .. " retries (some may be 0)")
end
end
local sf = sf_cache
-- ---- Inverter AC ----
-- AC power: 40083, I16
local ok_acw, acw_regs = pcall(host.modbus_read, 40083, 1, "input")
local ac_w = 0
if ok_acw and acw_regs then
ac_w = scale(host.decode_i16(acw_regs[1]), sf.ac_power)
end
-- Frequency: 40085, U16
local ok_hz, hz_regs = pcall(host.modbus_read, 40085, 1, "input")
local hz = 0
if ok_hz and hz_regs then
hz = scale(hz_regs[1], sf.hz)
end
-- Lifetime energy: 40093-40094, U32 BE (Wh once scaled)
local ok_le, le_regs = pcall(host.modbus_read, 40093, 2, "input")
local lifetime_wh = 0
if ok_le and le_regs then
lifetime_wh = scale(host.decode_u32_be(le_regs[1], le_regs[2]), sf.energy)
end
-- Heat-sink temperature: 40103, I16
local ok_temp, temp_regs = pcall(host.modbus_read, 40103, 1, "input")
local temp_c = 0
if ok_temp and temp_regs then
temp_c = scale(host.decode_i16(temp_regs[1]), sf.temp)
end
-- MPPT1 A/V: 40140-40141, U16 each
local ok_m1, m1_regs = pcall(host.modbus_read, 40140, 2, "input")
local mppt1_a, mppt1_v = 0, 0
if ok_m1 and m1_regs then
mppt1_a = scale(m1_regs[1], sf.mppt_a)
mppt1_v = scale(m1_regs[2], sf.mppt_v)
end
-- MPPT2 A/V: 40160-40161, U16 each
local ok_m2, m2_regs = pcall(host.modbus_read, 40160, 2, "input")
local mppt2_a, mppt2_v = 0, 0
if ok_m2 and m2_regs then
mppt2_a = scale(m2_regs[1], sf.mppt_a)
mppt2_v = scale(m2_regs[2], sf.mppt_v)
end
-- Emit PV (site convention: generation is negative W)
host.emit("pv", {
w = -ac_w,
mppt1_v = mppt1_v,
mppt1_a = mppt1_a,
mppt2_v = mppt2_v,
mppt2_a = mppt2_a,
lifetime_wh = lifetime_wh,
temp_c = temp_c,
})
host.emit_metric("pv_mppt1_v", mppt1_v)
host.emit_metric("pv_mppt1_a", mppt1_a)
host.emit_metric("pv_mppt2_v", mppt2_v)
host.emit_metric("pv_mppt2_a", mppt2_a)
host.emit_metric("inverter_temp_c", temp_c)
host.emit_metric("grid_hz", hz)
-- ---- Meter ----
-- Total W: 40100, I16
local ok_mw, mw_regs = pcall(host.modbus_read, 40100, 1, "input")
local meter_w = 0
if ok_mw and mw_regs then
meter_w = scale(host.decode_i16(mw_regs[1]), sf.meter_w)
end
-- Per-phase current: 40191-40193, I16 each
local ok_la, la_regs = pcall(host.modbus_read, 40191, 3, "input")
local l1_a, l2_a, l3_a = 0, 0, 0
if ok_la and la_regs then
l1_a = scale(host.decode_i16(la_regs[1]), sf.meter_a)
l2_a = scale(host.decode_i16(la_regs[2]), sf.meter_a)
l3_a = scale(host.decode_i16(la_regs[3]), sf.meter_a)
end
-- Per-phase voltage: 40196-40198, I16 each
local ok_lv, lv_regs = pcall(host.modbus_read, 40196, 3, "input")
local l1_v, l2_v, l3_v = 0, 0, 0
if ok_lv and lv_regs then
l1_v = scale(host.decode_i16(lv_regs[1]), sf.meter_v)
l2_v = scale(host.decode_i16(lv_regs[2]), sf.meter_v)
l3_v = scale(host.decode_i16(lv_regs[3]), sf.meter_v)
end
-- Per-phase power: 40207-40209, I16 each
local ok_lw, lw_regs = pcall(host.modbus_read, 40207, 3, "input")
local l1_w, l2_w, l3_w = 0, 0, 0
if ok_lw and lw_regs then
l1_w = scale(host.decode_i16(lw_regs[1]), sf.phase_w)
l2_w = scale(host.decode_i16(lw_regs[2]), sf.phase_w)
l3_w = scale(host.decode_i16(lw_regs[3]), sf.phase_w)
end
-- Export energy: 40226-40227, U32 BE
local ok_exp, exp_regs = pcall(host.modbus_read, 40226, 2, "input")
local export_wh = 0
if ok_exp and exp_regs then
export_wh = scale(host.decode_u32_be(exp_regs[1], exp_regs[2]), sf.meter_energy)
end
-- Import energy: 40234-40235, U32 BE
local ok_imp, imp_regs = pcall(host.modbus_read, 40234, 2, "input")
local import_wh = 0
if ok_imp and imp_regs then
import_wh = scale(host.decode_u32_be(imp_regs[1], imp_regs[2]), sf.meter_energy)
end
-- SolarEdge meter reports with sign inverted vs site convention.
-- Site: + = into site (import). SolarEdge: + = out (export).
-- So negate W and A to flip to site convention. V and Hz are unsigned.
host.emit("meter", {
w = -meter_w,
l1_w = -l1_w,
l2_w = -l2_w,
l3_w = -l3_w,
l1_v = l1_v,
l2_v = l2_v,
l3_v = l3_v,
l1_a = -l1_a,
l2_a = -l2_a,
l3_a = -l3_a,
hz = hz,
import_wh = import_wh,
export_wh = export_wh,
})
host.emit_metric("meter_l1_w", -l1_w)
host.emit_metric("meter_l2_w", -l2_w)
host.emit_metric("meter_l3_w", -l3_w)
host.emit_metric("meter_l1_v", l1_v)
host.emit_metric("meter_l2_v", l2_v)
host.emit_metric("meter_l3_v", l3_v)
host.emit_metric("meter_l1_a", -l1_a)
host.emit_metric("meter_l2_a", -l2_a)
host.emit_metric("meter_l3_a", -l3_a)
return 5000
end
----------------------------------------------------------------------------
-- Control (PV curtail only — meter + PV emission is read-only)
----------------------------------------------------------------------------
-- Atomic write of both F000 (enable) and F001 (limit) — single FC 0x10
-- (Write Multiple Holding Registers) transaction so the inverter never
-- sees a half-applied state (e.g. enable=1 still paired with the
-- previous tick's old limit, briefly capping at a stale value).
-- REG_APC_ENABLE is at 61440, REG_APC_LIMIT at 61441 → adjacent, so
-- one multi-register write covers both.
local function write_apc(enable, limit_pct)
local err = host.modbus_write_multi(REG_APC_ENABLE, { enable, limit_pct })
if err ~= nil and err ~= "" then
return false, tostring(err)
end
return true, nil
end
-- Apply a curtail limit in watts. Returns true on success, false on
-- any error (no nominal_w configured, modbus write failure).
local function apply_curtail(power_w)
if nominal_w <= 0 then
host.log("warn",
"SolarEdge: curtail requested but nominal_w not configured; ignoring")
return false
end
if power_w == nil or power_w < 0 then power_w = 0 end
local pct = math.floor((power_w / nominal_w) * 100 + 0.5)
if pct < 0 then pct = 0 end
if pct > 100 then pct = 100 end
local ok, err = write_apc(1, pct)
if not ok then
host.log("warn", "SolarEdge: write APC enable+limit failed: " .. err)
return false
end
curtail_active = true
host.log("info",
"SolarEdge: curtail " .. tostring(pct) .. "% (" .. tostring(power_w) ..
" W of " .. tostring(nominal_w) .. " W nominal)")
return true
end
-- Release the curtail cap. Atomically writes F000=0 and F001=100 so
-- both enable-bit-honoring and limit-value-honoring firmwares see a
-- coherent "no cap" state in a single transaction. We need both
-- writes: some HD-Wave / StorEdge firmwares ignore F000 and follow
-- F001 directly (stuck-at-3% bug if F001 isn't reset), others honor
-- F000 alone (cap held at F001's value while enabled).
local function release_curtail()
local ok, err = write_apc(0, 100)
if not ok then
host.log("warn", "SolarEdge: release APC enable+limit failed: " .. err)
return false
end
if curtail_active then
host.log("info", "SolarEdge: curtail released (APC_LIMIT=100, APC_ENABLE=0)")
end
curtail_active = false
return true
end
function driver_command(action, power_w, cmd)
if action == "curtail" then
return apply_curtail(power_w)
elseif action == "curtail_disable" or action == "deinit" then
return release_curtail()
end
host.log("debug", "SolarEdge: ignoring unsupported action=" .. tostring(action))
return false
end
function driver_default_mode()
-- "Default mode" on the watchdog path means "drop back to the
-- safe autonomous behavior". For a PV inverter that's just
-- releasing any curtail cap so the panels can produce normally.
release_curtail()
end
function driver_cleanup()
-- Best-effort: leave the inverter at full production when the
-- driver is unloaded or the process shuts down cleanly. If this
-- write fails (e.g. modbus connection already torn down), the
-- operator must clear the cap manually via SetApp.
release_curtail()
end