Current situation

The CEP stimulus documentation currently presents a single <Stimulus> element and does not describe the multiple-stimulus capability added in SimVascular/svMultiPhysics#586.

This PR updates the documentation to describe repeated <Stimulus> elements within the same domain, independent stimulus evaluation, additive behavior for overlapping active stimuli, and the relevant default behavior.

Closes #101

Release Notes

  • Document repeated CEP <Stimulus> elements within one domain.
  • Document independent timing, amplitude, and spatial bounds for each stimulus.
  • Document summation when multiple stimuli are active at the same node and time.
  • Clarify zero-, one-, and multiple-stimulus behavior.
  • Clarify amplitude and cycle-length defaults.

Documentation

Updated:

documentation/multi_physics/solver-input-file/domain_parameters/readme.md

Code of Conduct & Contributing Guidelines

@ktbolt

ktbolt commented Jul 16, 2026

Copy link
Copy Markdown
Contributor

@samibismar Looks good !

@ktbolt
ktbolt merged commit 3014734 into SimVascular:main Jul 16, 2026