di-omics · evaluation notes

How each capability in the di-omics portfolio is evaluated: the metric it is scored on, the QC that gates it, and which numbers are still pending.

Rendered: https://di-omics.github.io/benchmarks/

Two axes

Each repo is checked on two axes.

Science: does the result hold? The physical biology and chemistry executed correctly, and the bioinformatics recovers ground truth, against a metric fixed before the run. This is not cleared by an in-silico recovery score alone; the wet step has to be shown to have run correctly.

Autonomy: does it run unattended? Physical-AI QC in the loop, error handling that fails closed, and closed-loop feedback where the agent reads QC, corrects, and re-runs.

The infrastructure behind the checks

Pillar What it is State
Liquid-handling QC Rhodamine B for per-well CV%, Qubit / PicoGreen for yield. Upfront, fail-closed. Verified
Computer-vision QC Reads wells, pipetting, and steps from bench video. Ground-truth-validated. Verified
Error handling Guards, do-not-over-dry limits, one approval before purchase. Fails closed on readiness. Verified
Robust bioinformatics Reproducible fastq-to-result pipelines: scanpy, BJ-WGS Nextflow, versioned. Verified
Preset statistics Metric and acceptance threshold fixed before the run. Plant ground truth, recover, score. Verified
Closed-loop agentic feedback Agent reads QC and CV, corrects the deck, and re-runs without a human in the path. Building

Guardrails against fooling ourselves

  • Threshold before the run. The metric and the pass line are fixed up front, not chosen after the numbers land.
  • Physical execution is measured, not trusted. Rhodamine B, Qubit, and computer vision confirm the wet step actually happened correctly.
  • In silico alone does not clear the science axis. A recovery score on synthetic data is a start, not a pass.

Per-capability status

Capability Science axis (physical + bioinformatics) Autonomy axis (QC + closed loop) Graded by (preset) Expert in loop
fullstack-omics UMI counts, low-input recovery, coverage; wet chemistry to run on deck. Building End to end in the PyLabRobot simulator; scWGS 10/10 tests. Verified scanpy, BJ-WGS concordance operator at deck
plr-mcp Actions execute on liquid handler, reader, cycler, shaker. Verified MCP tool-call round-trip; CI green on 3.10-3.13. Verified simulator + hardware handshake agent proposes, operator confirms
omics-demos Recovery vs. planted ground truth across nine assays. Verified Blind run, per-assay recovery score. Verified recovery score, threshold preset none, automated eval
plr-minimum-effective Yield held at reduced reagent; wet confirmation pending. Building Bayesian optimization, held-out recovery. Verified cross-validated recovery expert sets acceptance floor
plr-clarity Rhodamine-B validation ladder on a real deck; biovalidated tier. Building Plan text compiled into a runnable method. Verified validation tier reached expert signs each tier
lab-cv Wells filled vs. empty, pipetting correct. Verified ROI motion QC + detection on protocol video, CPU-only. Verified ground-truth-validated frames reviewer adjudicates

Verified is runnable and checkable now. Building means the infrastructure is in place and the wet number is next to land. Numbers are never invented: a Building cell names the metric and waits for a measured value.

Source: github.com/di-omics

About

How di-omics evaluates its lab-automation work: the metric each capability is scored on (physical execution and bioinformatics), the QC that gates it, and which numbers are still pending.