🌊 Sluice Gate Level Control Simulator

Simulate and tune a sluice gate that controls water level in an open channel.

Quick Start

uv sync --dev
uv run streamlit run sluice_sim/ui/app.py

A browser tab opens with the simulator dashboard.

How to Use

1. Run a Simulation

  1. Click ▶ Run — the simulation runs with default settings
  2. Three tabs appear:
    • 📈 Main Plots — water level, gate opening (cm), flow rates
    • 📊 Error & Duty — controller error and motor duty cycle
    • 🎬 Schematic Animation — animated GIF of the channel

2. Adjust Parameters

Open the sidebar (left side) to change settings. Each parameter has a ⓘ tooltip — hover over it for an explanation.

Section What you can change
📐 Geometry Channel width, length, max gate opening, discharge coefficient, max water level
⚡ Motor Gate open/close speed (cm/s)
🎛 Controller PID gains (Kp, Ki, Kd), filter, pulse timing, duty scaling
🔇 Deadband Error thresholds to prevent motor chattering
💧 Inflow Profile Choose Constant / Step / Ramp / Sine disturbance
🕹 Simulation Initial level, setpoint, time step, duration, noise

After changing parameters, click ▶ Run again.

3. Auto-Tune the Controller

Not sure what PID gains to use? Let the simulator find them:

  1. In the sidebar, expand 🔧 Auto-Tune PID
  2. Pick a tuning rule (e.g. "Ziegler-Nichols PI")
  3. Click Run Auto-Tune
  4. Copy the recommended Kp / Ki / Kd values into the 🎛 Controller section
  5. Click ▶ Run to test

4. Export Results

After running a simulation, scroll down to find:

  • Download CSV — full time-series data
  • Download Scenario JSON — all parameter settings (can be loaded back later)

To reload a saved scenario, use the Load scenario file uploader next to the Run button.

Summary Metrics

After each run, a 📊 Summary section shows:

Metric Meaning
Final H Water level at the end
Final gate Gate opening at the end (cm)
Peak H Highest water level reached — shows ⚠ OVERFLOW if near limit
Steady-state error How close H stays to the setpoint at the end
Settling time (2%) How quickly H reaches and stays within ±2% of setpoint

Key Concepts

  • H_set — the target water level the controller tries to maintain
  • H_max — maximum water level before overflow (water is clamped here)
  • a_eq — the equilibrium gate opening that perfectly balances inflow at the setpoint
  • Gate opening — displayed in cm everywhere
  • The controller uses pulse modulation: it sends OPEN/CLOSE/STOP commands to the motor in timed pulses, not continuous movement

Running Tests

uv run pytest sluice_sim/tests/ -v

Project Files

sluice_sim/
├── models/plant.py          # Physics: channel, gate, motor
├── controllers/
│   ├── pid_pulse.py         # PID controller with pulse modulation
│   └── autotune.py          # Auto-tuning via relay feedback
├── profiles/inflow.py       # Inflow disturbance profiles
├── sim/simulator.py         # Runs the simulation loop
├── ui/app.py                # Streamlit dashboard
└── tests/                   # Unit tests

About

ATL sluice gate simulator for PID controller tuning

Topics

Resources

Stars

0 stars

Watchers

0 watching

Forks

Releases

Packages

Contributors

Languages