Add OCP ehanced optical telemetry info support for Credo CMIS modules - #738
Draft
nathanpage-credo wants to merge 1 commit into
Conversation
Adds link-quality/FEC/eye/optical-power telemetry for Credo CMIS modules that support the vendor "Get Telemetry Info" CDB command (opcode 0x8000), merged into TRANSCEIVER_DOM_REAL_VALUE. Follows the CmisEnhancedLpoApi/CmisEnhancedLpoMemMap convention: the module keeps the standard CmisMemMap as its main EEPROM map, with the vendor CDB commands handled by a dedicated internal CdbMemMap-based handler (mirroring CmisApi's own cdb_fw_hdlr/_cdb_mem_map pattern).
|
Collaborator
|
/azp run |
|
Azure Pipelines: There may be pipelines that require an authorized user to comment /azp run to run. |
|
Azure Pipelines: Successfully started running 1 pipeline(s). |
Collaborator
|
Hi, there are workflow run(s) waiting for approval, you may be first-time contributor. I will notify maintainers to help approve once PR is approved. Thanks! ---Powered by SONiC BuildBot
|
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Description
Adds link-quality/FEC/eye/optical-power telemetry for Credo CMIS modules that support the vendor "Get Telemetry Info" CDB command (opcode 0x8000), merged into TRANSCEIVER_DOM_REAL_VALUE. Follows the CmisEnhancedLpoApi/CmisEnhancedLpoMemMap convention: the module keeps the standard CmisMemMap as its main EEPROM map, with the vendor CDB commands handled by a dedicated internal CdbMemMap-based handler (mirroring CmisApi's own cdb_fw_hdlr/_cdb_mem_map pattern).
Motivation and Context
How Has This Been Tested?
Additional Information (Optional)