You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Local control of an ACiQ/Midea HVAC system whose only smart interface is a cloud-bound TL04-1 wall thermostat. An ESP32 bridges onto the air handler's XYE service bus over RS-485 and presents it to Home Assistant, alongside a pixel-matched replica of the thermostat's screen.
Reverse-engineered UART protocol for an ACiQ K18W mini split (TCL WBR1 dongle, CN-16). 115200 8N1 with 0xA5 framing - not TCL tclac, not Midea, not Tuya. Includes an ESPHome listen-only decoder for Home Assistant.